Evaluation of a Workflow to Define Low Specific Absorption Rate MRI Protocols for Patients With Active Implantable Medical Devices. Issue 1 (10th January 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of a Workflow to Define Low Specific Absorption Rate MRI Protocols for Patients With Active Implantable Medical Devices. Issue 1 (10th January 2020)
- Main Title:
- Evaluation of a Workflow to Define Low Specific Absorption Rate MRI Protocols for Patients With Active Implantable Medical Devices
- Authors:
- Martinez, Jessica A.
Moulin, Kévin
Yoo, Bryan
Shi, Yu
Kim, Hyun J.
Villablanca, Pablo J.
Ennis, Daniel B. - Abstract:
- Abstract : Background: MRI exams for patients with MR‐conditional active implantable medical devices (AIMDs) are contraindicated unless specific conditions are met. This limits the maximum specific absorption rate (SAR, W/kg). Currently, there is no general framework to guide meeting a lower SAR limit. Purpose: To design and evaluate a workflow for modifying MRI protocols to whole‐body SAR (WB‐SAR ≤0.1 W/kg) and local‐head SAR (LH‐SAR ≤0.3 W/kg) limits while mitigating the impact on image quality and exam time. Study Type: Prospective. Population: Twenty healthy volunteers on head ( n = 5), C‐spine ( n = 5), T‐spine ( n = 5), and L‐spine ( n = 5) with IRB consent. Assessment: Vendor‐provided head, C‐spine, T‐spine, and L‐spine protocols (SARRT ) were modified to meet both low SAR targets (SARLOW ) using the proposed workflow. in vitro SNR and CNR were evaluated with a T1 ‐T2 phantom. in vivo image quality and clinical acceptability were scored using a 5‐point Likert scale for two blinded readers. Field Strength/Sequences: 1.5T/spin‐echoes, gradient‐echoes. Statistical Analysis: In vitro SNR and CNR values were evaluated with a repeated measures general linear model. in vivo image quality and clinical acceptability were evaluated using a generalized estimating equation analysis (GEE). The two reader's level of agreement was analyzed using Cohen's kappa statistical analysis. Results: Using the workflow, SAR limits were met. LH‐SAR: 0.12 ± 0.02 W/kg, median (SD) values forAbstract : Background: MRI exams for patients with MR‐conditional active implantable medical devices (AIMDs) are contraindicated unless specific conditions are met. This limits the maximum specific absorption rate (SAR, W/kg). Currently, there is no general framework to guide meeting a lower SAR limit. Purpose: To design and evaluate a workflow for modifying MRI protocols to whole‐body SAR (WB‐SAR ≤0.1 W/kg) and local‐head SAR (LH‐SAR ≤0.3 W/kg) limits while mitigating the impact on image quality and exam time. Study Type: Prospective. Population: Twenty healthy volunteers on head ( n = 5), C‐spine ( n = 5), T‐spine ( n = 5), and L‐spine ( n = 5) with IRB consent. Assessment: Vendor‐provided head, C‐spine, T‐spine, and L‐spine protocols (SARRT ) were modified to meet both low SAR targets (SARLOW ) using the proposed workflow. in vitro SNR and CNR were evaluated with a T1 ‐T2 phantom. in vivo image quality and clinical acceptability were scored using a 5‐point Likert scale for two blinded readers. Field Strength/Sequences: 1.5T/spin‐echoes, gradient‐echoes. Statistical Analysis: In vitro SNR and CNR values were evaluated with a repeated measures general linear model. in vivo image quality and clinical acceptability were evaluated using a generalized estimating equation analysis (GEE). The two reader's level of agreement was analyzed using Cohen's kappa statistical analysis. Results: Using the workflow, SAR limits were met. LH‐SAR: 0.12 ± 0.02 W/kg, median (SD) values for LH‐SAR were 0.12 (0.02) W/kg and WB‐SAR: 0.09 (0.01) W/kg. Examination time did not increase ≤2x the initial time. SARRT SNR values were higher and significantly different than SARLOW ( P < 0.05). However, no significant difference was observed between the CNR values (value = 0.21). Median (IQR) CNR values were 14.2 (25.0) vs. 15.1 (9.2) for head, 12.1 (16.9) vs. 25.3 (14.2) for C‐spine, 81.6 (70.1) vs. 71.0 (26.6) for T‐spine, and 51.4 (52.6) vs. 37.7 (27.3) for L‐spine. Image quality scores were not significantly different between SARRT and SARLOW (median [SD] scores were 4.0 [0.01] vs. 4.3 [0.2], P > 0.05). Data Conclusion: The proposed workflow provides guidance for modifying routine MRI exams to achieve low SAR limits. This can benefit patients referred for an MRI exam with low SAR MR‐conditional AIMDs. Level of Evidence: 1 Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2020;52:91–102. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 52:Issue 1(2020)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 52:Issue 1(2020)
- Issue Display:
- Volume 52, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 52
- Issue:
- 1
- Issue Sort Value:
- 2020-0052-0001-0000
- Page Start:
- 91
- Page End:
- 102
- Publication Date:
- 2020-01-10
- Subjects:
- MRI -- MR‐safety -- SAR -- low SAR -- MR‐conditional -- active implantable medical devices
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.27044 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13335.xml