A Pulsatile Flow System to Engineer Aneurysm and Atherosclerosis Mimetic Extracellular Matrix. Issue 12 (30th April 2020)
- Record Type:
- Journal Article
- Title:
- A Pulsatile Flow System to Engineer Aneurysm and Atherosclerosis Mimetic Extracellular Matrix. Issue 12 (30th April 2020)
- Main Title:
- A Pulsatile Flow System to Engineer Aneurysm and Atherosclerosis Mimetic Extracellular Matrix
- Authors:
- Hosseini, Vahid
Mallone, Anna
Mirkhani, Nima
Noir, Jerome
Salek, Mehdi
Pasqualini, Francesco Silvio
Schuerle, Simone
Khademhosseini, Ali
Hoerstrup, Simon P.
Vogel, Viola - Abstract:
- Abstract: Alterations of blood flow patterns strongly correlate with arterial wall diseases such as atherosclerosis and aneurysm. Here, a simple, pumpless, close‐loop, easy‐to‐replicate, and miniaturized flow device is introduced to concurrently expose 3D engineered vascular smooth muscle tissues to high‐velocity pulsatile flow versus low‐velocity disturbed flow conditions. Two flow regimes are distinguished, one that promotes elastin and impairs collagen I assembly, while the other impairs elastin and promotes collagen assembly. This latter extracellular matrix (ECM) composition shares characteristics with aneurysmal or atherosclerotic tissue phenotypes, thus recapitulating crucial hallmarks of flow‐induced tissue morphogenesis in vessel walls. It is shown that the mRNA levels of ECM of collagens and elastin are not affected by the differential flow conditions. Instead, the differential gene expression of matrix metalloproteinase (MMP) and their inhibitors (TIMPs) is flow‐dependent, and thus drives the alterations in ECM composition. In further support, treatment with doxycycline, an MMP inhibitor and a clinically used drug to treat vascular diseases, halts the effect of low‐velocity flow on the ECM remodeling. This illustrates how the platform can be exploited for drug efficacy studies by providing crucial mechanistic insights into how different therapeutic interventions may affect tissue growth and ECM assembly. Abstract : Alterations of hemodynamics are associated withAbstract: Alterations of blood flow patterns strongly correlate with arterial wall diseases such as atherosclerosis and aneurysm. Here, a simple, pumpless, close‐loop, easy‐to‐replicate, and miniaturized flow device is introduced to concurrently expose 3D engineered vascular smooth muscle tissues to high‐velocity pulsatile flow versus low‐velocity disturbed flow conditions. Two flow regimes are distinguished, one that promotes elastin and impairs collagen I assembly, while the other impairs elastin and promotes collagen assembly. This latter extracellular matrix (ECM) composition shares characteristics with aneurysmal or atherosclerotic tissue phenotypes, thus recapitulating crucial hallmarks of flow‐induced tissue morphogenesis in vessel walls. It is shown that the mRNA levels of ECM of collagens and elastin are not affected by the differential flow conditions. Instead, the differential gene expression of matrix metalloproteinase (MMP) and their inhibitors (TIMPs) is flow‐dependent, and thus drives the alterations in ECM composition. In further support, treatment with doxycycline, an MMP inhibitor and a clinically used drug to treat vascular diseases, halts the effect of low‐velocity flow on the ECM remodeling. This illustrates how the platform can be exploited for drug efficacy studies by providing crucial mechanistic insights into how different therapeutic interventions may affect tissue growth and ECM assembly. Abstract : Alterations of hemodynamics are associated with vascular wall diseases. A simple, pumpless, close‐loop, easy‐to‐replicate flow device to engineer de novo‐grown disease‐like extracellular matrix of vascular wall tissues is proposed. Mechanistic insights of a clinically practiced matrix metalloproteinase inhibitor used to treat aneurysm and atherosclerosis, and on how the stage of the disease might affect the efficacy of the treatment are gained. … (more)
- Is Part Of:
- Advanced science. Volume 7:Issue 12(2020)
- Journal:
- Advanced science
- Issue:
- Volume 7:Issue 12(2020)
- Issue Display:
- Volume 7, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 12
- Issue Sort Value:
- 2020-0007-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-04-30
- Subjects:
- aneurysms -- arterial wall diseases -- atherosclerosis -- extracellular matrix -- human vascular smooth muscle cells -- in vitro 3D tissue models -- pulsatile flow
Science -- Periodicals
505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2198-3844 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/advs.202000173 ↗
- Languages:
- English
- ISSNs:
- 2198-3844
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13331.xml