Fast contour propagation for MR‐guided prostate radiotherapy using convolutional neural networks. Issue 3 (23rd January 2020)
- Record Type:
- Journal Article
- Title:
- Fast contour propagation for MR‐guided prostate radiotherapy using convolutional neural networks. Issue 3 (23rd January 2020)
- Main Title:
- Fast contour propagation for MR‐guided prostate radiotherapy using convolutional neural networks
- Authors:
- Eppenhof, K.A.J.
Maspero, M.
Savenije, M.H.F.
de Boer, J.C.J.
van der Voort van Zyp, J.R.N.
Raaymakers, B.W.
Raaijmakers, A.J.E.
Veta, M.
van den Berg, C.A.T.
Pluim, J.P.W. - Abstract:
- Abstract : Purpose: To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)‐guided prostate external‐beam radiotherapy. Methods: Five prostate cancer patients underwent 20 fractions of image‐guided external‐beam radiotherapy on a 1.5 T MR‐Linac system. For each patient, a pretreatment T2‐weighted three‐dimensional (3D) MR imaging (MRI) scan was used to delineate the clinical target volume (CTV) contours. The same scan was repeated during each fraction, with the CTV contour being manually adapted if necessary. A convolutional neural network (CNN) was trained for combined image registration and contour propagation. The network estimated the propagated contour and a deformation field between the two input images. The training set consisted of a synthetically generated ground truth of randomly deformed images and prostate segmentations. We performed a leave‐one‐out cross‐validation on the five patients and propagated the prostate segmentations from the pretreatment to the fraction scans. Three variants of the CNN, aimed at investigating supervision based on optimizing segmentation overlap, optimizing the registration, and a combination of the two were compared to results of the open‐source deformable registration software package Elastix. Results: The neural networks trained on segmentation overlap or the combined objective achieved significantly better Hausdorff distances between predicted and ground truth contoursAbstract : Purpose: To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)‐guided prostate external‐beam radiotherapy. Methods: Five prostate cancer patients underwent 20 fractions of image‐guided external‐beam radiotherapy on a 1.5 T MR‐Linac system. For each patient, a pretreatment T2‐weighted three‐dimensional (3D) MR imaging (MRI) scan was used to delineate the clinical target volume (CTV) contours. The same scan was repeated during each fraction, with the CTV contour being manually adapted if necessary. A convolutional neural network (CNN) was trained for combined image registration and contour propagation. The network estimated the propagated contour and a deformation field between the two input images. The training set consisted of a synthetically generated ground truth of randomly deformed images and prostate segmentations. We performed a leave‐one‐out cross‐validation on the five patients and propagated the prostate segmentations from the pretreatment to the fraction scans. Three variants of the CNN, aimed at investigating supervision based on optimizing segmentation overlap, optimizing the registration, and a combination of the two were compared to results of the open‐source deformable registration software package Elastix. Results: The neural networks trained on segmentation overlap or the combined objective achieved significantly better Hausdorff distances between predicted and ground truth contours than Elastix, at the much faster registration speed of 0.5 s. The CNN variant trained to optimize both the prostate overlap and deformation field, and the variant trained to only maximize the prostate overlap, produced the best propagation results. Conclusions: A CNN trained on maximizing prostate overlap and minimizing registration errors provides a fast and accurate method for deformable contour propagation for prostate MR‐guided radiotherapy. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 3(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 3(2020)
- Issue Display:
- Volume 47, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2020-0047-0003-0000
- Page Start:
- 1238
- Page End:
- 1248
- Publication Date:
- 2020-01-23
- Subjects:
- contour propagation -- deep learning -- image registration -- MR-guided radiotherapy -- prostate
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13994 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13308.xml