The trigonometric orthogonality of phase‐stepping curves in grating‐based x‐ray phase‐contrast imaging: Integral property and its implications for noise optimization. Issue 3 (30th December 2019)
- Record Type:
- Journal Article
- Title:
- The trigonometric orthogonality of phase‐stepping curves in grating‐based x‐ray phase‐contrast imaging: Integral property and its implications for noise optimization. Issue 3 (30th December 2019)
- Main Title:
- The trigonometric orthogonality of phase‐stepping curves in grating‐based x‐ray phase‐contrast imaging: Integral property and its implications for noise optimization
- Authors:
- Wu, Chengpeng
Zhang, Li
Chen, Zhiqiang
Xing, Yuxiang
Li, Xinbin
Zhu, Xiaohua
Arboleda, Carolina
Wang, Zhentian
Gao, Hewei - Abstract:
- Abstract : Purpose: Grating‐based x‐ray phase‐contrast imaging (GPCI) is a promising technique for clinical applications as it can provide two newly emerging imaging modalities (differential phase‐contrast and dark‐field contrast) in addition to the conventional absorption contrast. As far, phase‐stepping strategy is the most commonly used approach in GPCI to indirectly acquire differential phase‐contrast and dark‐field contrast. It is known that the obtained phase‐stepping curves (PSCs) have the cosine property and the convolution property, leading to two types of information retrieval approaches in literature: the Fourier component analysis and the multi‐order moment analysis. The purpose of this paper is to derive a new property of PSCs and apply the property to noise optimization for information retrieval. Methods: Based on the cosine expression of the flat PSC without the sample and the well‐established convolution relationship between the flat PSC and the sample PSC, we reveal an important integral property of PSCs: the inner product of PSCs and an arbitrary function contains only zero‐order and first‐order components in the Fourier series. Furthermore, we apply the property to the direct multi‐order moment analysis and propose a set of generalized forms including an optimal one in the presence of noise. Results: To validate the effectiveness of our analysis, we compared the simulated and real experiment results retrieved by the original direct multi‐order momentAbstract : Purpose: Grating‐based x‐ray phase‐contrast imaging (GPCI) is a promising technique for clinical applications as it can provide two newly emerging imaging modalities (differential phase‐contrast and dark‐field contrast) in addition to the conventional absorption contrast. As far, phase‐stepping strategy is the most commonly used approach in GPCI to indirectly acquire differential phase‐contrast and dark‐field contrast. It is known that the obtained phase‐stepping curves (PSCs) have the cosine property and the convolution property, leading to two types of information retrieval approaches in literature: the Fourier component analysis and the multi‐order moment analysis. The purpose of this paper is to derive a new property of PSCs and apply the property to noise optimization for information retrieval. Methods: Based on the cosine expression of the flat PSC without the sample and the well‐established convolution relationship between the flat PSC and the sample PSC, we reveal an important integral property of PSCs: the inner product of PSCs and an arbitrary function contains only zero‐order and first‐order components in the Fourier series. Furthermore, we apply the property to the direct multi‐order moment analysis and propose a set of generalized forms including an optimal one in the presence of noise. Results: To validate the effectiveness of our analysis, we compared the simulated and real experiment results retrieved by the original direct multi‐order moment analysis with the ones retrieved by our proposed noise‐optimal form. A significant improvement of noise performance by our method is observed and the improvement ratio in differential phase‐contrast is consistent with our theoretical calculation (39.2%). Conclusions: In this paper, we reveal a new integral property of the acquired PSCs with and without samples in GPCI, which can be applied to information retrieval approaches like the direct multi‐order moment analysis. Then we optimize these approaches to improve the noise performance, offering great potentials of dose reduction in practical applications. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 3(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 3(2020)
- Issue Display:
- Volume 47, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2020-0047-0003-0000
- Page Start:
- 1189
- Page End:
- 1198
- Publication Date:
- 2019-12-30
- Subjects:
- grating‐based x‐ray imaging -- information retrieval -- noise -- x‐ray phase‐contrast imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13957 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13299.xml