Improvement in Quality of Life and Decrease in Large‐Volume Paracentesis Requirements With the Automated Low‐Flow Ascites Pump. Issue 5 (22nd March 2020)
- Record Type:
- Journal Article
- Title:
- Improvement in Quality of Life and Decrease in Large‐Volume Paracentesis Requirements With the Automated Low‐Flow Ascites Pump. Issue 5 (22nd March 2020)
- Main Title:
- Improvement in Quality of Life and Decrease in Large‐Volume Paracentesis Requirements With the Automated Low‐Flow Ascites Pump
- Authors:
- Wong, Florence
Bendel, Emily
Sniderman, Kenneth
Frederick, Todd
Haskal, Ziv J.
Sanyal, Arun
Asrani, Sumeet K.
Capel, Jeroen
Kamath, Patrick S. - Abstract:
- Abstract : The automated low‐flow ascites pump (alfapump) is an implantable device that drains ascites directly into the urinary bladder. We studied its safety (absence of serious complications) and efficacy (decreased large‐volume paracentesis [LVP] requirement and improved quality of life [QoL]) in the management of ascites in a cohort of North American patients with cirrhosis and recurrent ascites ineligible for transjugular intrahepatic portosystemic shunt (TIPS). QoL was measured by the Chronic Liver Disease Questionnaire (CLDQ) and Ascites Questionnaire (Ascites Q). Following alfapump implantation, patients were monitored for ascites control, laboratory abnormalities, QoL, adverse events, and survival at 12 months. A total of 30 patients (60.0 ± 9.9 years; 57% male; Model for End‐Stage Liver Disease score, 11.4 ± 2.7) received an alfapump, mostly by an interventional radiology approach (97%), followed by longterm prophylactic antibiotics. The alfapump removed a mean ascites volume of 230.6 ± 148.9 L/patient at 12 months, dramatically reducing the mean LVP frequency from 2.4 ± 1.4/patient/month before pump implantation to 0.2 ± 0.4/patient/month after pump implantation. All surviving patients had improved QoL (baseline versus 3 months; CLDQ, 3.9 ± 1.21 versus 5.0 ± 1.0; Ascites Q, 51.7 ± 21.9 versus 26.7 ± 18.6; P < 0.001 for both) and a better biochemical index of nutritional status (prealbumin 87.8 ± 37.5 versus 102.9 ± 45.3 mg/L at 3 months; P = 0.04). BacterialAbstract : The automated low‐flow ascites pump (alfapump) is an implantable device that drains ascites directly into the urinary bladder. We studied its safety (absence of serious complications) and efficacy (decreased large‐volume paracentesis [LVP] requirement and improved quality of life [QoL]) in the management of ascites in a cohort of North American patients with cirrhosis and recurrent ascites ineligible for transjugular intrahepatic portosystemic shunt (TIPS). QoL was measured by the Chronic Liver Disease Questionnaire (CLDQ) and Ascites Questionnaire (Ascites Q). Following alfapump implantation, patients were monitored for ascites control, laboratory abnormalities, QoL, adverse events, and survival at 12 months. A total of 30 patients (60.0 ± 9.9 years; 57% male; Model for End‐Stage Liver Disease score, 11.4 ± 2.7) received an alfapump, mostly by an interventional radiology approach (97%), followed by longterm prophylactic antibiotics. The alfapump removed a mean ascites volume of 230.6 ± 148.9 L/patient at 12 months, dramatically reducing the mean LVP frequency from 2.4 ± 1.4/patient/month before pump implantation to 0.2 ± 0.4/patient/month after pump implantation. All surviving patients had improved QoL (baseline versus 3 months; CLDQ, 3.9 ± 1.21 versus 5.0 ± 1.0; Ascites Q, 51.7 ± 21.9 versus 26.7 ± 18.6; P < 0.001 for both) and a better biochemical index of nutritional status (prealbumin 87.8 ± 37.5 versus 102.9 ± 45.3 mg/L at 3 months; P = 0.04). Bacterial infections (15 events in 13 patients), electrolyte abnormalities (11 events in 6 patients), and renal complications (11 events in 9 patients) were the most common severe adverse events. By 12 months, 4 patients died from complications of cirrhosis. Alfapump insertion may be a definitive treatment for refractory ascites in cirrhosis, especially in patients who are not TIPS candidates. … (more)
- Is Part Of:
- Liver transplantation. Volume 26:Issue 5(2020)
- Journal:
- Liver transplantation
- Issue:
- Volume 26:Issue 5(2020)
- Issue Display:
- Volume 26, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 26
- Issue:
- 5
- Issue Sort Value:
- 2020-0026-0005-0000
- Page Start:
- 651
- Page End:
- 661
- Publication Date:
- 2020-03-22
- Subjects:
- Liver -- Transplantation -- Periodicals
Liver -- Diseases -- Periodicals
Liver Transplantation -- Periodicals
Foie -- Greffe -- Périodiques
617.5560592 - Journal URLs:
- https://journals.lww.com/lt/pages/currenttoc.aspx#232431391 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lt.25724 ↗
- Languages:
- English
- ISSNs:
- 1527-6465
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5280.522000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13257.xml