Accuracy of intraocular lens power calculations in paediatric eyes. (10th January 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of intraocular lens power calculations in paediatric eyes. (10th January 2020)
- Main Title:
- Accuracy of intraocular lens power calculations in paediatric eyes
- Authors:
- Li, Jianbing
Liu, Zhenzhen
Wang, Ruixin
Cheng, Huanhuan
Zhao, Jing
Liu, Liangping
Chen, Weirong
Wu, Mingxing
Liu, Yizhi - Abstract:
- Abstract: Importance: There is no clear consensus on which intraocular lens (IOL) power calculation formula provides the best refractive prediction in the paediatric population. Background: To evaluate the predictability of desired postoperative refractive outcomes by using six IOL formulas in paediatric cataract cases. Design: Retrospective case series. Participants: A total of 377 eyes in 377 paediatric patients (<13 years of age) who received primary IOL implants in the capsular bag. Methods: This study utilized formulas, namely, SRK II, SRK/T, Hoffer Q, Holladay 1, T2 and Super formula. Prediction errors were calculated based on the difference between the postoperative refraction and the refraction predicted by each formula. Main Outcome Measures: The mean prediction error, mean absolute error, median absolute error, percentages of eyes within the prediction errors of ±0.50 D, ±1.00 D and ± 2.00 D. Results: The mean axial length was 22.48 ± 1.91 mm (<22.0 mm for 161 eyes). The average age at surgery was 55.21 ± 28.01 months (<24 months for 37 eyes). The mean prediction error was positive (hyperopic error) with all formulas. Compared to the other IOL power formulas, SRK II showed significantly higher absolute errors ( P < .001). Hoffer Q and Holladay 1 generated the least absolute error, followed closely by Super formula. Multiple logistic analyses indicated that age at time of surgery was an independent factor significantly contributing to the refractive surprise usingAbstract: Importance: There is no clear consensus on which intraocular lens (IOL) power calculation formula provides the best refractive prediction in the paediatric population. Background: To evaluate the predictability of desired postoperative refractive outcomes by using six IOL formulas in paediatric cataract cases. Design: Retrospective case series. Participants: A total of 377 eyes in 377 paediatric patients (<13 years of age) who received primary IOL implants in the capsular bag. Methods: This study utilized formulas, namely, SRK II, SRK/T, Hoffer Q, Holladay 1, T2 and Super formula. Prediction errors were calculated based on the difference between the postoperative refraction and the refraction predicted by each formula. Main Outcome Measures: The mean prediction error, mean absolute error, median absolute error, percentages of eyes within the prediction errors of ±0.50 D, ±1.00 D and ± 2.00 D. Results: The mean axial length was 22.48 ± 1.91 mm (<22.0 mm for 161 eyes). The average age at surgery was 55.21 ± 28.01 months (<24 months for 37 eyes). The mean prediction error was positive (hyperopic error) with all formulas. Compared to the other IOL power formulas, SRK II showed significantly higher absolute errors ( P < .001). Hoffer Q and Holladay 1 generated the least absolute error, followed closely by Super formula. Multiple logistic analyses indicated that age at time of surgery was an independent factor significantly contributing to the refractive surprise using all formulas. Conclusions and Relevance: SRK II was the least predictable formula in this study. HofferQ and Holladay 1 yielded the best predictive values. … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 48:Number 3(2020)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 48:Number 3(2020)
- Issue Display:
- Volume 48, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 48
- Issue:
- 3
- Issue Sort Value:
- 2020-0048-0003-0000
- Page Start:
- 301
- Page End:
- 310
- Publication Date:
- 2020-01-10
- Subjects:
- paediatric cataract -- intraocular lens power calculation -- formulas
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.13701 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13248.xml