Automated 3D geometry segmentation of the healthy and diseased carotid artery in free‐hand, probe tracked ultrasound images. Issue 3 (3rd January 2020)
- Record Type:
- Journal Article
- Title:
- Automated 3D geometry segmentation of the healthy and diseased carotid artery in free‐hand, probe tracked ultrasound images. Issue 3 (3rd January 2020)
- Main Title:
- Automated 3D geometry segmentation of the healthy and diseased carotid artery in free‐hand, probe tracked ultrasound images
- Authors:
- de Ruijter, Joerik
van Sambeek, Marc
van de Vosse, Frans
Lopata, Richard - Abstract:
- Abstract : Purpose: Rupture of an arterosclerotic plaque in the carotid artery is a major cause of stroke. Biomechanical analysis of plaques is under development aiming to aid the clinician in the assessment of plaque vulnerability. Patient‐specific three‐dimensional (3D) geometry assessment of the carotid artery, including the bifurcation, is required as input for these biomechanical models. This requires a high‐resolution, 3D, noninvasive imaging modality such as ultrasound (US). In this study, a high‐resolution two‐dimensional (2D) linear array in combination with a magnetic probe tracking device and automatic segmentation method was used to assess the geometry of the carotid artery. The advantages of using this system over a 3D ultrasound probe are its higher resolution (spatial and temporal) and its larger field of view. Methods: A slow sweep (v = ± 5 mm/s) was made over the subject's neck so that the full geometry of the bifurcated geometry of the carotid artery is captured. An automated segmentation pipeline was developed. First, the Star‐Kalman method was used to approximate the center and size of the vessels for every frame. Images were filtered with a Gaussian high‐pass filter before conversion into the 2D monogenic signals, and multiscale asymmetry features were extracted from these data, enhancing low lateral wall‐lumen contrast. These images, in combination with the initial ellipse contours, were used for an active deformable contour model to segment the vesselAbstract : Purpose: Rupture of an arterosclerotic plaque in the carotid artery is a major cause of stroke. Biomechanical analysis of plaques is under development aiming to aid the clinician in the assessment of plaque vulnerability. Patient‐specific three‐dimensional (3D) geometry assessment of the carotid artery, including the bifurcation, is required as input for these biomechanical models. This requires a high‐resolution, 3D, noninvasive imaging modality such as ultrasound (US). In this study, a high‐resolution two‐dimensional (2D) linear array in combination with a magnetic probe tracking device and automatic segmentation method was used to assess the geometry of the carotid artery. The advantages of using this system over a 3D ultrasound probe are its higher resolution (spatial and temporal) and its larger field of view. Methods: A slow sweep (v = ± 5 mm/s) was made over the subject's neck so that the full geometry of the bifurcated geometry of the carotid artery is captured. An automated segmentation pipeline was developed. First, the Star‐Kalman method was used to approximate the center and size of the vessels for every frame. Images were filtered with a Gaussian high‐pass filter before conversion into the 2D monogenic signals, and multiscale asymmetry features were extracted from these data, enhancing low lateral wall‐lumen contrast. These images, in combination with the initial ellipse contours, were used for an active deformable contour model to segment the vessel lumen. To segment the lumen–plaque boundary, Otsu's automatic thresholding method was used. Distension of the wall due to the change in blood pressure was removed using a filter approach. Finally, the contours were converted into a 3D hexahedral mesh for a patient‐specific solid mechanics model of the complete arterial wall. Results: The method was tested on 19 healthy volunteers and on 3 patients. The results were compared to manual segmentation performed by three experienced observers. Results showed an average Hausdorff distance of 0.86 mm and an average similarity index of 0.91 for the common carotid artery (CCA) and 0.88 for the internal and external carotid artery. For the total algorithm, the success rate was 89%, in 4 out of 38 datasets the ICA and ECA were not sufficient visible in the US images. Accurate 3D hexahedral meshes were successfully generated from the segmented images . Conclusions: With this method, a subject‐specific biomechanical model can be constructed directly from a hand‐held 2D US measurement, within 10 min, with a minimal user input. The performance of the proposed segmentation algorithm is comparable to or better than algorithms previously described in literature. Moreover, the algorithm is able to segment the CCA, ICA, and ECA including the carotid bifurcation in transverse B‐mode images in both healthy and diseased arteries. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 3(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 3(2020)
- Issue Display:
- Volume 47, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2020-0047-0003-0000
- Page Start:
- 1034
- Page End:
- 1047
- Publication Date:
- 2020-01-03
- Subjects:
- automated segmentation -- carotid artery bifurcation -- geometry assessment -- image analysis -- ultrasound
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13960 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13231.xml