Effect of patient size on image quality in radiotherapy kV planar verification imaging: a phantom study. Issue 1 (16th October 2019)
- Record Type:
- Journal Article
- Title:
- Effect of patient size on image quality in radiotherapy kV planar verification imaging: a phantom study. Issue 1 (16th October 2019)
- Main Title:
- Effect of patient size on image quality in radiotherapy kV planar verification imaging: a phantom study
- Authors:
- Chan, Sara
Giles, Eileen
Newmarch, Lyndal
Short, Michala - Other Names:
- Dobeli Dr Karen guestEditor.
Brown Dr Elizabeth guestEditor. - Abstract:
- Abstract: Introduction: This study aimed to determine a maximal pelvic separation and waist circumference in pelvic patients to guide radiation therapists in acquiring kilovoltage (kV) planar images of acceptable quality for treatment verification. Methods: A pelvic anthropomorphic phantom modified with different bolus thicknesses was imaged at various default kV exposure settings. Radiation therapists rated image quality and acceptance/rejection of these images for treatment verification. Results: Sixteen radiation therapists participated in the study. Image quality was inversely proportional to phantom size. AP and lateral kV images were acceptable for treatment verification up to a waist circumference of 143 cm. Conclusions: Exposure settings for kV image verification of large patients should be individualised to avoid unnecessary patient radiation dose through repeated imaging. Abstract : Exposure settings for radiotherapy image verification of large patients should be individualised to avoid unnecessary patient radiation dose through repeated imaging. This study found that radiation therapists rated image quality to be unacceptable for use in image verification beyond pelvic AP separation of 46.5 cm, lateral separation of 60 cm and the corresponding waist circumference of 169 cm.
- Is Part Of:
- Journal of medical radiation sciences. Volume 67:Issue 1(2020:Mar.)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 67:Issue 1(2020:Mar.)
- Issue Display:
- Volume 67, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 67
- Issue:
- 1
- Issue Sort Value:
- 2020-0067-0001-0000
- Page Start:
- 34
- Page End:
- 42
- Publication Date:
- 2019-10-16
- Subjects:
- image interpretation -- image‐guided radiotherapy -- phantoms -- waist circumference
Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.355 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13224.xml