Virtual 4DCT from 4DMRI for the management of respiratory motion in carbon ion therapy of abdominal tumors. Issue 3 (20th January 2020)
- Record Type:
- Journal Article
- Title:
- Virtual 4DCT from 4DMRI for the management of respiratory motion in carbon ion therapy of abdominal tumors. Issue 3 (20th January 2020)
- Main Title:
- Virtual 4DCT from 4DMRI for the management of respiratory motion in carbon ion therapy of abdominal tumors
- Authors:
- Meschini, Giorgia
Vai, Alessandro
Paganelli, Chiara
Molinelli, Silvia
Fontana, Giulia
Pella, Andrea
Preda, Lorenzo
Vitolo, Viviana
Valvo, Francesca
Ciocca, Mario
Riboldi, Marco
Baroni, Guido - Abstract:
- Abstract : Purpose: To evaluate a method for generating virtual four‐dimensional computed tomography (4DCT) from four‐dimensional magnetic resonance imaging (4DMRI) data in carbon ion radiotherapy with pencil beam scanning for abdominal tumors. Methods: Deformable image registration is used to: (a) register each respiratory phase of the 4DMRI to the end‐exhale MRI; (b) register the reference end‐exhale CT to the end‐exhale MRI volume; (c) generate the virtual 4DCT by warping the registered CT according to the obtained deformation fields. A respiratory‐gated carbon ion treatment plan is optimized on the planning 4DCT and the corresponding dose distribution is recalculated on the virtual 4DCT. The method was validated on a digital anthropomorphic phantom and tested on eight patients (18 acquisitions). For the phantom, a ground truth dataset was available to assess the method performances from the geometrical and dosimetric standpoints. For the patients, the virtual 4DCT was compared with the planning 4DCT. Results: In the phantom, the method exhibits a geometrical accuracy within the voxel size and Dose Volume Histograms deviations up to 3.3% for target V95% (mean dose difference ≤ 0.2% of the prescription dose, gamma pass rate > 98%). For patients, the virtual and the planning 4DCTs show good agreement at end‐exhale (3% median D95% difference), whereas other respiratory phases exhibit moderate motion variability with consequent dose discrepancies, confirming the need forAbstract : Purpose: To evaluate a method for generating virtual four‐dimensional computed tomography (4DCT) from four‐dimensional magnetic resonance imaging (4DMRI) data in carbon ion radiotherapy with pencil beam scanning for abdominal tumors. Methods: Deformable image registration is used to: (a) register each respiratory phase of the 4DMRI to the end‐exhale MRI; (b) register the reference end‐exhale CT to the end‐exhale MRI volume; (c) generate the virtual 4DCT by warping the registered CT according to the obtained deformation fields. A respiratory‐gated carbon ion treatment plan is optimized on the planning 4DCT and the corresponding dose distribution is recalculated on the virtual 4DCT. The method was validated on a digital anthropomorphic phantom and tested on eight patients (18 acquisitions). For the phantom, a ground truth dataset was available to assess the method performances from the geometrical and dosimetric standpoints. For the patients, the virtual 4DCT was compared with the planning 4DCT. Results: In the phantom, the method exhibits a geometrical accuracy within the voxel size and Dose Volume Histograms deviations up to 3.3% for target V95% (mean dose difference ≤ 0.2% of the prescription dose, gamma pass rate > 98%). For patients, the virtual and the planning 4DCTs show good agreement at end‐exhale (3% median D95% difference), whereas other respiratory phases exhibit moderate motion variability with consequent dose discrepancies, confirming the need for motion mitigation strategies during treatment. Conclusions: The virtual 4DCT approach is feasible to evaluate treatment plan robustness against intra‐ and interfraction motion in carbon ion therapy delivered at the abdominal site. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 3(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 3(2020)
- Issue Display:
- Volume 47, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2020-0047-0003-0000
- Page Start:
- 909
- Page End:
- 916
- Publication Date:
- 2020-01-20
- Subjects:
- 4DMRI -- carbon ion therapy -- motion management -- virtual 4DCT
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13992 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13220.xml