Multi‐site reproducibility of a human immunophenotyping assay in whole blood and peripheral blood mononuclear cells preparations using CyTOF technology coupled with Maxpar Pathsetter, an automated data analysis system. Issue 2 (23rd November 2019)
- Record Type:
- Journal Article
- Title:
- Multi‐site reproducibility of a human immunophenotyping assay in whole blood and peripheral blood mononuclear cells preparations using CyTOF technology coupled with Maxpar Pathsetter, an automated data analysis system. Issue 2 (23rd November 2019)
- Main Title:
- Multi‐site reproducibility of a human immunophenotyping assay in whole blood and peripheral blood mononuclear cells preparations using CyTOF technology coupled with Maxpar Pathsetter, an automated data analysis system
- Authors:
- Bagwell, Charles Bruce
Hunsberger, Benjamin
Hill, Beth
Herbert, Donald
Bray, Christopher
Selvanantham, Thirumahal
Li, Stephen
Villasboas, Jose C.
Pavelko, Kevin
Strausbauch, Michael
Rahman, Adeeb
Kelly, Gregory
Asgharzadeh, Shahab
Gomez‐Cabrero, Azucena
Behbehani, Gregory
Chang, Hsiaochi
Lyberger, Justin
Montgomery, Ruth
Zhao, Yujiao
Inokuma, Margaret
Goldberger, Ofir
Stelzer, Greg - Abstract:
- Abstract: High‐dimensional mass cytometry data potentially enable a comprehensive characterization of immune cells. In order to positively affect clinical trials and translational clinical research, this advanced technology needs to demonstrate a high reproducibility of results across multiple sites for both peripheral blood mononuclear cells (PBMC) and whole blood preparations. A dry 30‐marker broad immunophenotyping panel and customized automated analysis software were recently engineered and are commercially available as the Fluidigm® Maxpar® Direct™ Immune Profiling Assay™. In this study, seven sites received whole blood and six sites received PBMC samples from single donors over a 2‐week interval. Each site labeled replicate samples and acquired data on Helios™ instruments using an assay‐specific acquisition template. All acquired sample files were then automatically analyzed by Maxpar Pathsetter™ software. A cleanup step eliminated debris, dead cells, aggregates, and normalization beads. The second step automatically enumerated 37 immune cell populations and performed label intensity assessments on all 30 markers. The inter‐site reproducibility of the 37 quantified cell populations had consistent population frequencies, with an average %CV of 14.4% for whole blood and 17.7% for PBMC. The dry reagent coupled with automated data analysis is not only convenient but also provides a high degree of reproducibility within and among multiple test sites resulting in aAbstract: High‐dimensional mass cytometry data potentially enable a comprehensive characterization of immune cells. In order to positively affect clinical trials and translational clinical research, this advanced technology needs to demonstrate a high reproducibility of results across multiple sites for both peripheral blood mononuclear cells (PBMC) and whole blood preparations. A dry 30‐marker broad immunophenotyping panel and customized automated analysis software were recently engineered and are commercially available as the Fluidigm® Maxpar® Direct™ Immune Profiling Assay™. In this study, seven sites received whole blood and six sites received PBMC samples from single donors over a 2‐week interval. Each site labeled replicate samples and acquired data on Helios™ instruments using an assay‐specific acquisition template. All acquired sample files were then automatically analyzed by Maxpar Pathsetter™ software. A cleanup step eliminated debris, dead cells, aggregates, and normalization beads. The second step automatically enumerated 37 immune cell populations and performed label intensity assessments on all 30 markers. The inter‐site reproducibility of the 37 quantified cell populations had consistent population frequencies, with an average %CV of 14.4% for whole blood and 17.7% for PBMC. The dry reagent coupled with automated data analysis is not only convenient but also provides a high degree of reproducibility within and among multiple test sites resulting in a comprehensive yet practical solution for deep immune phenotyping. … (more)
- Is Part Of:
- Cytometry. Volume 98:Issue 2(2020)
- Journal:
- Cytometry
- Issue:
- Volume 98:Issue 2(2020)
- Issue Display:
- Volume 98, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 98
- Issue:
- 2
- Issue Sort Value:
- 2020-0098-0002-0000
- Page Start:
- 146
- Page End:
- 160
- Publication Date:
- 2019-11-23
- Subjects:
- cytometry automation -- cytometry standardization -- kits -- percentage precision
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21858 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13188.xml