Is it safe to irradiate the newest generation of ventricular assist devices? A case report and systematic literature review. Issue 5 (15th January 2020)
- Record Type:
- Journal Article
- Title:
- Is it safe to irradiate the newest generation of ventricular assist devices? A case report and systematic literature review. Issue 5 (15th January 2020)
- Main Title:
- Is it safe to irradiate the newest generation of ventricular assist devices? A case report and systematic literature review
- Authors:
- Spano, Giancarlo
Stutz, Emanuel
Elicin, Olgun
Hugi, Beate
Henzen, Dominik
Fürholz, Monika
Wieser, Monika
Rhyner, Daniel
Dobner, Stephan
Pavlicek‐Bahlo, Maryam
Robson, Desiree
Nadel, James
Hayward, Christopher
Hunziker, Lukas
Martinelli, Michele
Schnegg, Bruno - Abstract:
- Abstract: An increasing number of mechanical assist devices, especially left ventricular assist devices (VADs), are being implanted for prolonged periods and as destination therapy. Some VAD patients require radiotherapy due to concomitant oncologic morbidities, including thoracic malignancies. This raises the potential of VAD malfunction via radiation‐induced damage. So far, only case reports and small case series on radiotherapy have been published, most of them on HeartMate II (HMII, Abbott, North Chicago, IL, USA). Significantly, the effects of irradiation on the HeartMate 3 (HM3, Abbott) remain undefined, despite the presence of controller components engineered within the pump itself. We report the first case of a patient with a HM3 who successfully underwent stereotactic hypofractionated radiotherapy due to an early‐stage non‐small‐cell lung cancer. The patient did not suffer from any complications, including toxicity or VAD malfunction. Based on this case report and on published literature, we think that performing radiotherapy after VAD implantation with the aid of a multidisciplinary team could be performed, but more in vitro studies and cases series are needed to reinforce this statement.
- Is Part Of:
- Artificial organs. Volume 44:Issue 5(2020)
- Journal:
- Artificial organs
- Issue:
- Volume 44:Issue 5(2020)
- Issue Display:
- Volume 44, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2020-0044-0005-0000
- Page Start:
- 449
- Page End:
- 456
- Publication Date:
- 2020-01-15
- Subjects:
- HeartMate 3 -- non‐small‐cell lung cancer -- radiotherapy -- ventricular assist device
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.13612 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13185.xml