A Wearable Capacitive Sensor Based on Ring/Disk‐Shaped Electrode and Porous Dielectric for Noncontact Healthcare Monitoring. Issue 5 (18th March 2020)
- Record Type:
- Journal Article
- Title:
- A Wearable Capacitive Sensor Based on Ring/Disk‐Shaped Electrode and Porous Dielectric for Noncontact Healthcare Monitoring. Issue 5 (18th March 2020)
- Main Title:
- A Wearable Capacitive Sensor Based on Ring/Disk‐Shaped Electrode and Porous Dielectric for Noncontact Healthcare Monitoring
- Authors:
- Zheng, Ya‐Nan
Yu, Zhe
Mao, Guoyong
Li, Yunyao
Pravarthana, Dhanapal
Asghar, Waqas
Liu, Yiwei
Qu, Shaoxing
Shang, Jie
Li, Run‐Wei - Abstract:
- Abstract: Wearable sensors are gradually enabling decentralized healthcare systems. However, these sensors need to be closely attached to skin, which is unsuitable for long‐term dynamic health monitoring of the patients, such as infants or persons with burn injuries. Here, a wearable capacitive sensor based on the capacitively coupled effect for healthcare monitoring in noncontact mode is reported. It consists of a ring‐shaped top electrode, a disk‐shaped bottom electrode, and a porous dielectric layer with low permittivity. This unique design enhanced the capacitively coupled effect of the sensor, which enables a high noncontact detectivity of capacitance change. When an object approaches the sensor, its capacitance change (Δ C / C i = −38.7%) is 3–5 times higher than that of previously reported sensors. Meanwhile, the sensor is insensitive to the stretching strain and pressure (Δ C / C i < 5%) due to the unique ring‐shaped electrode and the incompressible closed cells of the porous dielectric material, respectively. Finally, various human physiological signals (pulse and respiratory) are recorded in noncontact mode, where a person wears loose and soft clothes implanted with the sensor. Thus, it is promising to build smart healthcare clothes based on it to develop wearable decentralized healthcare systems. Abstract : A wearable capacitive sensor for noncontact healthcare monitoring consists of a ring‐shaped top electrode, a disk‐shaped bottom electrode, and a porousAbstract: Wearable sensors are gradually enabling decentralized healthcare systems. However, these sensors need to be closely attached to skin, which is unsuitable for long‐term dynamic health monitoring of the patients, such as infants or persons with burn injuries. Here, a wearable capacitive sensor based on the capacitively coupled effect for healthcare monitoring in noncontact mode is reported. It consists of a ring‐shaped top electrode, a disk‐shaped bottom electrode, and a porous dielectric layer with low permittivity. This unique design enhanced the capacitively coupled effect of the sensor, which enables a high noncontact detectivity of capacitance change. When an object approaches the sensor, its capacitance change (Δ C / C i = −38.7%) is 3–5 times higher than that of previously reported sensors. Meanwhile, the sensor is insensitive to the stretching strain and pressure (Δ C / C i < 5%) due to the unique ring‐shaped electrode and the incompressible closed cells of the porous dielectric material, respectively. Finally, various human physiological signals (pulse and respiratory) are recorded in noncontact mode, where a person wears loose and soft clothes implanted with the sensor. Thus, it is promising to build smart healthcare clothes based on it to develop wearable decentralized healthcare systems. Abstract : A wearable capacitive sensor for noncontact healthcare monitoring consists of a ring‐shaped top electrode, a disk‐shaped bottom electrode, and a porous dielectric layer to enhance the capacitively coupled effect. When an object approaches, its capacitance change is 3–5 times higher than that of reported capacitive sensors. Smart clothing implanted with this sensor successfully records the physiological signals by noncontact mode. … (more)
- Is Part Of:
- Global challenges. Volume 4:Issue 5(2020)
- Journal:
- Global challenges
- Issue:
- Volume 4:Issue 5(2020)
- Issue Display:
- Volume 4, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 5
- Issue Sort Value:
- 2020-0004-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-03-18
- Subjects:
- capacitively coupled effect -- dielectric materials wearable sensors -- noncontact healthcare monitoring
Climatic changes -- Periodicals
Sustainable development -- Periodicals
Globalization -- Environmental aspects -- Periodicals
Electronic journals
Periodicals
500 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2056-6646 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/gch2.201900079 ↗
- Languages:
- English
- ISSNs:
- 2056-6646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13161.xml