MRI‐visible liquid crystal thermometer. Issue 3 (28th February 2020)
- Record Type:
- Journal Article
- Title:
- MRI‐visible liquid crystal thermometer. Issue 3 (28th February 2020)
- Main Title:
- MRI‐visible liquid crystal thermometer
- Authors:
- Keenan, Kathryn E.
Stupic, Karl F.
Russek, Stephen E.
Mirowski, Elizabeth - Abstract:
- Abstract : Purpose: MRI parameters, such as T1, T2, and ADC, of tissue‐mimicking materials in MRI phantoms can exhibit temperature dependence, and bore temperatures can vary over a 10°C range across different MRI systems. If this variation is not accurately corrected for, the quantitative nature of reference or phantom measurements is irrelevant. Available thermometers require opening the phantoms to probe the temperature, which can introduce contaminants that may affect the stability and accuracy of the phantom. An integrated, MRI‐visible thermometer that can be read using typical imaging protocols is needed. Theory and Methods: An MRI‐compatible thermometer was designed using liquid crystals (LCs) that exhibit rapid transitions between the LC cholesteric state and isotropic state in the room temperature range spanning 17°C to 23°C in 1.0°C increments. The LC thermometer was assessed visually and using superconducting quantum interference device magnetometry, NMR, and MRI techniques. Results: The signal generated from the LC thermometer was visible with spin‐echo and gradient‐echo MRI images. The LC state transition temperatures were visually referenced to a National Institute of Standards and Technology‐traceable thermometer, and these LC state transitions were confirmed using superconducting quantum interference device magnetometry and NMR. Conclusions: The LC MR‐visible thermometer had measurable changes in relative signal with temperature, which were invariant to aAbstract : Purpose: MRI parameters, such as T1, T2, and ADC, of tissue‐mimicking materials in MRI phantoms can exhibit temperature dependence, and bore temperatures can vary over a 10°C range across different MRI systems. If this variation is not accurately corrected for, the quantitative nature of reference or phantom measurements is irrelevant. Available thermometers require opening the phantoms to probe the temperature, which can introduce contaminants that may affect the stability and accuracy of the phantom. An integrated, MRI‐visible thermometer that can be read using typical imaging protocols is needed. Theory and Methods: An MRI‐compatible thermometer was designed using liquid crystals (LCs) that exhibit rapid transitions between the LC cholesteric state and isotropic state in the room temperature range spanning 17°C to 23°C in 1.0°C increments. The LC thermometer was assessed visually and using superconducting quantum interference device magnetometry, NMR, and MRI techniques. Results: The signal generated from the LC thermometer was visible with spin‐echo and gradient‐echo MRI images. The LC state transition temperatures were visually referenced to a National Institute of Standards and Technology‐traceable thermometer, and these LC state transitions were confirmed using superconducting quantum interference device magnetometry and NMR. Conclusions: The LC MR‐visible thermometer had measurable changes in relative signal with temperature, which were invariant to a variety of imaging sequences used. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 3(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 3(2020)
- Issue Display:
- Volume 84, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 3
- Issue Sort Value:
- 2020-0084-0003-0000
- Page Start:
- 1552
- Page End:
- 1563
- Publication Date:
- 2020-02-28
- Subjects:
- liquid crystals -- MRI -- phantom -- temperature -- thermometer
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28224 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13156.xml