Technical performance of a novel, fully automated electrochemiluminescence immunoassay for the quantitation of β‐amyloid (1–42) in human cerebrospinal fluid. Issue 5 (7th November 2015)
- Record Type:
- Journal Article
- Title:
- Technical performance of a novel, fully automated electrochemiluminescence immunoassay for the quantitation of β‐amyloid (1–42) in human cerebrospinal fluid. Issue 5 (7th November 2015)
- Main Title:
- Technical performance of a novel, fully automated electrochemiluminescence immunoassay for the quantitation of β‐amyloid (1–42) in human cerebrospinal fluid
- Authors:
- Bittner, Tobias
Zetterberg, Henrik
Teunissen, Charlotte E.
Ostlund, Richard E.
Militello, Michael
Andreasson, Ulf
Hubeek, Isabelle
Gibson, David
Chu, David C.
Eichenlaub, Udo
Heiss, Peter
Kobold, Uwe
Leinenbach, Andreas
Madin, Kairat
Manuilova, Ekaterina
Rabe, Christina
Blennow, Kaj - Abstract:
- Abstract: Introduction: Available assays for quantitation of the Alzheimer's disease (AD) biomarker amyloid‐beta 1–42 (Aβ [1–42]) in cerebrospinal fluid demonstrate significant variability and lack of standardization to reference measurement procedures (RMPs). We report analytical performance data for the novel Elecsys β‐amyloid (1–42) assay (Roche Diagnostics). Methods: Lot‐to‐lot comparability was tested using method comparison. Performance parameters were measured according to Clinical & Laboratory Standards Institute (CLSI) guidelines. The assay was standardized to a Joint Committee for Traceability in Laboratory Medicine (JCTLM) approved RMP. Results: Limit of quantitation was <11.28 pg/mL, and the assay was linear throughout the measuring range (200–1700 pg/mL). Excellent lot‐to‐lot comparability was observed (correlation coefficients [Pearson's r] >0.995; bias in medical decision area <2%). Repeatability coefficients of variation (CVs) were 1.0%–1.6%, intermediate CVs were 1.9%–4.0%, and intermodule CVs were 1.1%–3.9%. Estimated total reproducibility was 2.0%–5.1%. Correlation with the RMP was good (Pearson's r, 0.93). Discussion: The Elecsys β‐amyloid (1–42) assay has high analytical performance that may improve biomarker‐based AD diagnosis.
- Is Part Of:
- Alzheimer's & dementia. Volume 12:Issue 5(2016)
- Journal:
- Alzheimer's & dementia
- Issue:
- Volume 12:Issue 5(2016)
- Issue Display:
- Volume 12, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 12
- Issue:
- 5
- Issue Sort Value:
- 2016-0012-0005-0000
- Page Start:
- 517
- Page End:
- 526
- Publication Date:
- 2015-11-07
- Subjects:
- Amyloid -- Amyloid‐beta 1–42 -- Alzheimer's disease -- Assay -- Biomarker -- Cerebrospinal fluid -- Dementia -- Diagnosis -- Electrochemiluminescence -- Immunoassay -- Method comparison -- Precision -- Repeatability -- Reproducibility -- Variability
Alzheimer's disease -- Periodicals
Alzheimer Disease -- Periodicals
Dementia -- Periodicals
Démence
Maladie d'Alzheimer
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.83 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15525260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jalz.2015.09.009 ↗
- Languages:
- English
- ISSNs:
- 1552-5260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0806.255333
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13159.xml