Direct visual targeting versus preset coordinates for ANT‐DBS in epilepsy. (10th March 2020)
- Record Type:
- Journal Article
- Title:
- Direct visual targeting versus preset coordinates for ANT‐DBS in epilepsy. (10th March 2020)
- Main Title:
- Direct visual targeting versus preset coordinates for ANT‐DBS in epilepsy
- Authors:
- Nome, Terje
Herrman, Helle
Lehtimäki, Kai
Egge, Arild
Konglund, Ane
Ramm-Pettersen, Jon
Taubøll, Erik
Dietrichs, Espen - Abstract:
- Abstract : Objectives: Deep brain stimulation (DBS) of the anterior thalamic nucleus (ANT) may be used against refractory focal epilepsy, but only two randomized double‐blinded trials have been performed. The Oslo study was discontinued prematurely since reduction in seizure frequency was less than expected. The aim of the present study was to review the targeting used in the Oslo study and to identify the actual positions of the contacts used for stimulation. Material and methods: BrainLab MRI data were available from 12 Oslo study patients. Based on MRI the coordinates of the center of the ANT were identified. The coordinates were considered as the visually identified preferred target and were compared with the target originally used for ANT electrode implantation and with the actual electrode positions estimated from post‐operative CT scans. Results: We found considerable differences between the visually identified preferred target, the originally planned target, and the actual electrode position. The total distance between the active electrode position and the visually identified preferred target was on average 3.3 mm on the right and 2.9 mm on the left side. Conclusion: Indirect targeting based on preset coordinates may contribute to explain the modest effect of ANT‐DBS on seizure frequency seen in the Oslo study. Observed differences between the center of the ANT and the actual electrode position may at least in part be explained by variations in position and size ofAbstract : Objectives: Deep brain stimulation (DBS) of the anterior thalamic nucleus (ANT) may be used against refractory focal epilepsy, but only two randomized double‐blinded trials have been performed. The Oslo study was discontinued prematurely since reduction in seizure frequency was less than expected. The aim of the present study was to review the targeting used in the Oslo study and to identify the actual positions of the contacts used for stimulation. Material and methods: BrainLab MRI data were available from 12 Oslo study patients. Based on MRI the coordinates of the center of the ANT were identified. The coordinates were considered as the visually identified preferred target and were compared with the target originally used for ANT electrode implantation and with the actual electrode positions estimated from post‐operative CT scans. Results: We found considerable differences between the visually identified preferred target, the originally planned target, and the actual electrode position. The total distance between the active electrode position and the visually identified preferred target was on average 3.3 mm on the right and 2.9 mm on the left side. Conclusion: Indirect targeting based on preset coordinates may contribute to explain the modest effect of ANT‐DBS on seizure frequency seen in the Oslo study. Observed differences between the center of the ANT and the actual electrode position may at least in part be explained by variations in position and size of the ANT. Direct identification of the target using better MRI imaging protocols is recommended for future ANT‐DBS surgery. … (more)
- Is Part Of:
- Acta neurologica Scandinavica. Volume 142:Number 1(2020)
- Journal:
- Acta neurologica Scandinavica
- Issue:
- Volume 142:Number 1(2020)
- Issue Display:
- Volume 142, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 142
- Issue:
- 1
- Issue Sort Value:
- 2020-0142-0001-0000
- Page Start:
- 23
- Page End:
- 29
- Publication Date:
- 2020-03-10
- Subjects:
- anterior nucleus of thalamus -- deep brain stimulation -- epilepsy
Neurology -- Periodicals
616.8 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/ane.13233 ↗
- Languages:
- English
- ISSNs:
- 0001-6314
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0639.910000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13156.xml