Voice‐Related Quality of Life Increases With a Talking Tracheostomy Tube: A Randomized Controlled Trial. (6th August 2019)
- Record Type:
- Journal Article
- Title:
- Voice‐Related Quality of Life Increases With a Talking Tracheostomy Tube: A Randomized Controlled Trial. (6th August 2019)
- Main Title:
- Voice‐Related Quality of Life Increases With a Talking Tracheostomy Tube: A Randomized Controlled Trial
- Authors:
- Pandian, Vinciya
Cole, Therese
Kilonsky, Dana
Holden, Kate
Feller‐Kopman, David J.
Brower, Roy
Mirski, Marek - Abstract:
- Abstract : Objective: The primary objective of our study was to determine the quality of life (QOL) using a talking tracheostomy tube. Methods: Randomized clinical trial (NCT2018562). Adult intensive care unit patients who were mechanically ventilated, awake, alert, attempting to communicate, English‐speaking, and could not tolerate one‐way speaking valve were included. Intervention comprised a Blue Line Ultra Suctionaid (BLUSA) talking tracheostomy tube (Smiths Medical, Dublin, OH, US). Outcome measures included QOL scores measured using Quality of Life in Mechanically Ventilated Patients (QOL‐MV) and Voice‐Related Quality of Life (V‐RQOL), Speech Intelligibility Test (SIT) scores, independence, and satisfaction. Results: The change in V‐RQOL scores from pre‐ to postintervention was higher among patients using a BLUSA (Smiths Medical) compared to those who did not ( P = 0.001). The QOL‐MV scores from pre‐ to postintervention were significantly higher among patients who used a BLUSA (Smiths Medical) compared to patients who did not use BLUSA (Smiths Medical) or a one‐way speaking valve ( P = 0.04). SIT scores decreased by 6.4 points for each 1‐point increase in their Sequential Organ Failure Assessment scores ( P = 0.04). The overall QOL‐MV scores correlated moderately with the overall V‐RQOL scores (correlation coefficient = 0.59). Cronbach alpha score for overall QOL‐MV was 0.71. Seventy‐three percent of the 22 intervention patients reported the ability to use the BLUSAAbstract : Objective: The primary objective of our study was to determine the quality of life (QOL) using a talking tracheostomy tube. Methods: Randomized clinical trial (NCT2018562). Adult intensive care unit patients who were mechanically ventilated, awake, alert, attempting to communicate, English‐speaking, and could not tolerate one‐way speaking valve were included. Intervention comprised a Blue Line Ultra Suctionaid (BLUSA) talking tracheostomy tube (Smiths Medical, Dublin, OH, US). Outcome measures included QOL scores measured using Quality of Life in Mechanically Ventilated Patients (QOL‐MV) and Voice‐Related Quality of Life (V‐RQOL), Speech Intelligibility Test (SIT) scores, independence, and satisfaction. Results: The change in V‐RQOL scores from pre‐ to postintervention was higher among patients using a BLUSA (Smiths Medical) compared to those who did not ( P = 0.001). The QOL‐MV scores from pre‐ to postintervention were significantly higher among patients who used a BLUSA (Smiths Medical) compared to patients who did not use BLUSA (Smiths Medical) or a one‐way speaking valve ( P = 0.04). SIT scores decreased by 6.4 points for each 1‐point increase in their Sequential Organ Failure Assessment scores ( P = 0.04). The overall QOL‐MV scores correlated moderately with the overall V‐RQOL scores (correlation coefficient = 0.59). Cronbach alpha score for overall QOL‐MV was 0.71. Seventy‐three percent of the 22 intervention patients reported the ability to use the BLUSA (Smiths Medical) with some level of independence, whereas 41% reported some level of satisfaction with the use of BLUSA (Smiths Medical). The lengths of stay was longer in the intervention group. Conclusion: Our study suggests that BLUSA (Smiths Medical) talking tracheostomy tube improves patient‐reported QOL in mechanically ventilated patients with a tracheostomy who cannot tolerate cuff deflation. Level of Evidence: I Laryngoscope, 130:1249–1255, 2020 … (more)
- Is Part Of:
- Laryngoscope. Volume 130:Number 5(2020)
- Journal:
- Laryngoscope
- Issue:
- Volume 130:Number 5(2020)
- Issue Display:
- Volume 130, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 5
- Issue Sort Value:
- 2020-0130-0005-0000
- Page Start:
- 1249
- Page End:
- 1255
- Publication Date:
- 2019-08-06
- Subjects:
- Voice -- mechanical ventilation -- quality of life -- tracheostomy -- critically ill
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.28211 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13157.xml