Accuracy of cone beam computed tomography in evaluation of palatal mucosa thickness. (13th February 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of cone beam computed tomography in evaluation of palatal mucosa thickness. (13th February 2020)
- Main Title:
- Accuracy of cone beam computed tomography in evaluation of palatal mucosa thickness
- Authors:
- Ogawa, Miho
Katagiri, Sayaka
Koyanagi, Tatsuro
Maekawa, Shogo
Shiba, Takahiko
Ohsugi, Yujin
Takeuchi, Yasuo
Ikawa, Takahiro
Takeuchi, Shogo
Sekiuchi, Takayuki
Arai, Yuki
Kazama, Ryunosuke
Wakabayashi, Noriyuki
Izumi, Yuichi
Iwata, Takanori - Abstract:
- Abstract: Aim: The purpose of this study was to investigate the accuracy of the measurement of palatal mucosa thickness using cone beam computed tomography (CBCT) and to create a conversion formula to evaluate palatal mucosa thickness more accurately. We then evaluated the palatal mucosa thickness in a Japanese population using CBCT and the conversion formula. Materials and methods: We evaluated palatal mucosa thickness in 10 healthy subjects at 15 sites using CBCT, digital impression, and K file. Multiple regression analysis was performed to create a conversion formula to measure thickness accurately. We then obtained CBCT data from 174 patients retrospectively, applied the conversion formula, and evaluated palatal mucosa thickness. Results: Sites of measurement affected measurement error. Measurement using CBCT was 0.34 ± 0.04 mm smaller than actual measurement; therefore, a conversion formula was created. Male, age ≥60 years, and probing pocket depth ≥4 mm had significant and positive associations with palatal mucosa thickness; however, no association was observed between bleeding on probing and palatal mucosa thickness. Conclusion: CBCT is useful for the noninvasive and accurate measurement of palatal mucosa thickness.
- Is Part Of:
- Journal of clinical periodontology. Volume 47:Number 4(2020)
- Journal:
- Journal of clinical periodontology
- Issue:
- Volume 47:Number 4(2020)
- Issue Display:
- Volume 47, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2020-0047-0004-0000
- Page Start:
- 479
- Page End:
- 488
- Publication Date:
- 2020-02-13
- Subjects:
- CBCT -- diagnostic imaging -- digital impression -- palatal mucosa thickness
Periodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cpe ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-051X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jcpe.13254 ↗
- Languages:
- English
- ISSNs:
- 0303-6979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.672000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13152.xml