Evaluation of image quality of pituitary dynamic contrast‐enhanced MRI using time‐resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT‐TWIST). Issue 5 (18th October 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of image quality of pituitary dynamic contrast‐enhanced MRI using time‐resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT‐TWIST). Issue 5 (18th October 2019)
- Main Title:
- Evaluation of image quality of pituitary dynamic contrast‐enhanced MRI using time‐resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT‐TWIST)
- Authors:
- Yokota, Yusuke
Fushimi, Yasutaka
Okada, Tomohisa
Fujimoto, Koji
Oshima, Sonoko
Nakajima, Satoshi
Fujii, Toshihito
Tanji, Masahiro
Inagaki, Nobuya
Miyamoto, Susumu
Togashi, Kaori - Abstract:
- Abstract : Background: Time‐resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k ‐space data and view‐sharing for the peripheral k ‐space of dynamic phases. IT‐TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction. Purpose: To compare image quality between TWIST and IT‐TWIST in 3D pituitary DCE‐MRI. Study Type: Retrospective observation study. Population: Fifty‐one patients (23 men, 28 women) who underwent 3D pituitary DCE‐MRI using TWIST between July 2016 and April 2017. Field Strength/Sequence: 3T/TWIST and IT‐TWIST. Assessment: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT‐TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT‐TWIST. Statistical Tests: Paired t ‐test or Wilcoxon rank‐sum test was used to test the differences between TWIST and IT‐TWIST in both visual evaluation and region of interest evaluation. Results: Scores of visual evaluations for IT‐TWIST were significantly better than those forAbstract : Background: Time‐resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k ‐space data and view‐sharing for the peripheral k ‐space of dynamic phases. IT‐TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction. Purpose: To compare image quality between TWIST and IT‐TWIST in 3D pituitary DCE‐MRI. Study Type: Retrospective observation study. Population: Fifty‐one patients (23 men, 28 women) who underwent 3D pituitary DCE‐MRI using TWIST between July 2016 and April 2017. Field Strength/Sequence: 3T/TWIST and IT‐TWIST. Assessment: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT‐TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT‐TWIST. Statistical Tests: Paired t ‐test or Wilcoxon rank‐sum test was used to test the differences between TWIST and IT‐TWIST in both visual evaluation and region of interest evaluation. Results: Scores of visual evaluations for IT‐TWIST were significantly better than those for TWIST ( P < 0.001) in all items. Enhancement slope for IT‐TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus ( P < 0.001). Temporal SD for IT‐TWIST was significantly lower than that for TWIST in all items, with statistical significance ( P < 0.001). Data Conclusion: IT‐TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE‐MRI. Evidence Level: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1497–1506. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 51:Issue 5(2020)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 51:Issue 5(2020)
- Issue Display:
- Volume 51, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 51
- Issue:
- 5
- Issue Sort Value:
- 2020-0051-0005-0000
- Page Start:
- 1497
- Page End:
- 1506
- Publication Date:
- 2019-10-18
- Subjects:
- magnetic resonance imaging -- pituitary gland -- central nervous system
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26962 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13142.xml