Characterization of Adnexal Masses Using Contrast‐Enhanced Subharmonic Imaging: A Pilot Study. (26th November 2019)
- Record Type:
- Journal Article
- Title:
- Characterization of Adnexal Masses Using Contrast‐Enhanced Subharmonic Imaging: A Pilot Study. (26th November 2019)
- Main Title:
- Characterization of Adnexal Masses Using Contrast‐Enhanced Subharmonic Imaging: A Pilot Study
- Authors:
- Delaney, Lauren J.
Machado, Priscilla
Torkzaban, Mehnoosh
Lyshchik, Andrej
Wessner, Corinne E.
Kim, Christine
Rosenblum, Norman
Richard, Scott
Wallace, Kirk
Forsberg, Flemming - Abstract:
- Abstract : Objectives: This pilot study evaluated whether contrast‐enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention. Methods: Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction‐replenishment SHI across the lesions. Time‐intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time‐intensity curve), which were compared to pathologic characterizations of the lesions. Results: Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologistAbstract : Objectives: This pilot study evaluated whether contrast‐enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention. Methods: Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction‐replenishment SHI across the lesions. Time‐intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time‐intensity curve), which were compared to pathologic characterizations of the lesions. Results: Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologist reads were combined with the most predictive quantitative SHI parameter (percent perfusion), diagnostic accuracy improved to 84% for the experienced radiologist and 96% for the novice radiologist. Conclusions: Results indicate that SHI for presurgical characterization of adnexal masses may improve the determination of malignancy and diagnostic accuracy, albeit based on a small sample size. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 39:Number 5(2020)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 39:Number 5(2020)
- Issue Display:
- Volume 39, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 5
- Issue Sort Value:
- 2020-0039-0005-0000
- Page Start:
- 977
- Page End:
- 985
- Publication Date:
- 2019-11-26
- Subjects:
- adnexal masses -- contrast agents -- diagnostics -- subharmonic imaging
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15183 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13141.xml