Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3‐year multicentre randomized controlled proof‐of‐concept study. (3rd February 2020)
- Record Type:
- Journal Article
- Title:
- Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3‐year multicentre randomized controlled proof‐of‐concept study. (3rd February 2020)
- Main Title:
- Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3‐year multicentre randomized controlled proof‐of‐concept study
- Authors:
- Salvi, Giovanni E.
Moëne, Raphaël
Wallkamm, Beat
Hicklin, Stefan P.
Bischof, Mark
Nedir, Rabah
Mombelli, Andrea
Sculean, Anton - Abstract:
- Abstract: Background: Surface modification may yield enhanced soft tissue adhesion to transmucosal titanium implant necks. Aim: To evaluate and compare changes in soft tissues around implants with a modified hydrophilic sandblasted and acid‐etched neck (mSLA; test) to those with a machined neck (M; control). Materials and methods: Implants with a diameter of 4.1 mm and a neck height of 1.8 mm were randomly inserted in healed sites with pristine bone of the posterior maxilla or mandible. The modified Sulcus Bleeding Index (mSBI) (primary outcome) was assessed at baseline (BL) and 6, 12 and 36 months. Secondary outcomes included the assessment of pocket probing depth (PPD), mucosal recession (REC) and clinical attachment level (CAL). Standardized radiographs were taken at time of implant placement, at BL and after 12 and 36 months. Results: Of the 43 randomized subjects, 38 (19 test and 19 controls) completed the 36‐month follow‐up. Implant survival rates amounted to 95.5% (test) and 100% (control) ( p > .05). At 36 months, 77.6% of test implants and 78.9% of control implants were without any bleeding sites (mSBI = 0; p > .05). The 36‐month success rate was 86.4% in the test and 85.7% in the control group, respectively ( p > .05). At 36 months, the mean radiographic bone level change from BL was 0.33 ± 0.69 mm at test implants and 0.12 ± 0.3 mm at control implants ( p > .05). Conclusion: Tissue level implants with a hydrophilic mSLA transmucosal neck failed to yieldAbstract: Background: Surface modification may yield enhanced soft tissue adhesion to transmucosal titanium implant necks. Aim: To evaluate and compare changes in soft tissues around implants with a modified hydrophilic sandblasted and acid‐etched neck (mSLA; test) to those with a machined neck (M; control). Materials and methods: Implants with a diameter of 4.1 mm and a neck height of 1.8 mm were randomly inserted in healed sites with pristine bone of the posterior maxilla or mandible. The modified Sulcus Bleeding Index (mSBI) (primary outcome) was assessed at baseline (BL) and 6, 12 and 36 months. Secondary outcomes included the assessment of pocket probing depth (PPD), mucosal recession (REC) and clinical attachment level (CAL). Standardized radiographs were taken at time of implant placement, at BL and after 12 and 36 months. Results: Of the 43 randomized subjects, 38 (19 test and 19 controls) completed the 36‐month follow‐up. Implant survival rates amounted to 95.5% (test) and 100% (control) ( p > .05). At 36 months, 77.6% of test implants and 78.9% of control implants were without any bleeding sites (mSBI = 0; p > .05). The 36‐month success rate was 86.4% in the test and 85.7% in the control group, respectively ( p > .05). At 36 months, the mean radiographic bone level change from BL was 0.33 ± 0.69 mm at test implants and 0.12 ± 0.3 mm at control implants ( p > .05). Conclusion: Tissue level implants with a hydrophilic mSLA transmucosal neck failed to yield clinical and radiographic benefits compared with implants with a machined neck up to 3 years. … (more)
- Is Part Of:
- Journal of clinical periodontology. Volume 47:Number 4(2020)
- Journal:
- Journal of clinical periodontology
- Issue:
- Volume 47:Number 4(2020)
- Issue Display:
- Volume 47, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2020-0047-0004-0000
- Page Start:
- 500
- Page End:
- 508
- Publication Date:
- 2020-02-03
- Subjects:
- dental implant -- implant surface modification -- soft tissue integration -- titanium -- transmucosal
Periodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cpe ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-051X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jcpe.13249 ↗
- Languages:
- English
- ISSNs:
- 0303-6979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.672000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13152.xml