Design of microfluidic experimental setup for the detection of heavy metal ions using piezoresistive BioMEMS sensor. Issue 1 (3rd November 2019)
- Record Type:
- Journal Article
- Title:
- Design of microfluidic experimental setup for the detection of heavy metal ions using piezoresistive BioMEMS sensor. Issue 1 (3rd November 2019)
- Main Title:
- Design of microfluidic experimental setup for the detection of heavy metal ions using piezoresistive BioMEMS sensor
- Authors:
- Rotake, Dinesh Ramkrushna
Darji, Anand D.
Kale, Nitin S. - Abstract:
- Abstract : Purpose: This paper aims to propose a new microfluidic portable experimental platform for quick detection of heavy metal ions (HMIs) in picomolar range. The experimental setup uses a microfabricated piezoresistive sensor (MPS) array of eight cantilevers with ion-selective self-assembled monolayer's (SAM). Design/methodology/approach: Most of the components used in this experimental setup are battery operated and, hence, portable to perform the on-field experiments. HMIs (antigen) and thiol-based SAM (antibody) interaction start bending the microcantilever. This results in a change of resistance, which is directly proportional to the surface stress produced due to the mass of targeted HMIs. The authors have used Cysteamine and 4-Mercaptobenzoic acid as a thiol for creating SAM to test the sensitivity and identify the suitable thiol. Some of the cantilevers are blocked using acetyl chloride to use as a reference for error detection. Findings: The portable experimental platform achieves very small detection time of 10-25 min with a lower limit of detection (LOD) 0.762 ng (6.05 pM) for SAM of Cysteamine and 4-Mercaptobenzoic acid to detect Mn2+ ions. This technique has excellent potential and capability to selectively detect Hg2+ ions as low as 2.43 pM/mL using SAM of Homocysteine (Hcys)-Pyridinedicarboxylic acid (PDCA). Research limitations/implications: As microcantilever is very thin and fragile, it is challenging to apply a surface coating to have selectiveAbstract : Purpose: This paper aims to propose a new microfluidic portable experimental platform for quick detection of heavy metal ions (HMIs) in picomolar range. The experimental setup uses a microfabricated piezoresistive sensor (MPS) array of eight cantilevers with ion-selective self-assembled monolayer's (SAM). Design/methodology/approach: Most of the components used in this experimental setup are battery operated and, hence, portable to perform the on-field experiments. HMIs (antigen) and thiol-based SAM (antibody) interaction start bending the microcantilever. This results in a change of resistance, which is directly proportional to the surface stress produced due to the mass of targeted HMIs. The authors have used Cysteamine and 4-Mercaptobenzoic acid as a thiol for creating SAM to test the sensitivity and identify the suitable thiol. Some of the cantilevers are blocked using acetyl chloride to use as a reference for error detection. Findings: The portable experimental platform achieves very small detection time of 10-25 min with a lower limit of detection (LOD) 0.762 ng (6.05 pM) for SAM of Cysteamine and 4-Mercaptobenzoic acid to detect Mn2+ ions. This technique has excellent potential and capability to selectively detect Hg2+ ions as low as 2.43 pM/mL using SAM of Homocysteine (Hcys)-Pyridinedicarboxylic acid (PDCA). Research limitations/implications: As microcantilever is very thin and fragile, it is challenging to apply a surface coating to have selective detection using Nanadispenser. Some of the cantilevers get broken during this process. Originality/value: The excessive use and commercialization of NPs are quickly expanding their toxic impact on health and the environment. Also, LOD is limited to nanomolar range. The proposed method used the combination of thin-film, NPs, and MEMS-based technology to overcome the limitation of NPs-based technique and have picomolar range of HMIs detection. … (more)
- Is Part Of:
- Microelectronics international. Volume 37:Issue 1(2020)
- Journal:
- Microelectronics international
- Issue:
- Volume 37:Issue 1(2020)
- Issue Display:
- Volume 37, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2020-0037-0001-0000
- Page Start:
- 10
- Page End:
- 28
- Publication Date:
- 2019-11-03
- Subjects:
- Micro Electro Mechanical Systems (MEMS) -- Piezoresistive sensors -- BioMEMS -- microfluidics -- Limit of detection (LOD) -- SAM (self assembled monolayer's) -- Heavy metal ions (HMIs)
Microelectronics -- Periodicals
621.381 - Journal URLs:
- http://info.emeraldinsight.com/products/journals/journals.htm?PHPSESSID=1turhlb3hk8vmsfsbt4nv991s5&id=mi ↗
http://info.emeraldinsight.com/products/journals/journals.htm?id=mi ↗
http://www.emeraldinsight.com/ ↗ - DOI:
- 10.1108/MI-05-2019-0025 ↗
- Languages:
- English
- ISSNs:
- 1356-5362
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5758.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13123.xml