Cardiac implantable electronic devices in patients with persistent left superior vena cava—A single center experience. (8th April 2020)
- Record Type:
- Journal Article
- Title:
- Cardiac implantable electronic devices in patients with persistent left superior vena cava—A single center experience. (8th April 2020)
- Main Title:
- Cardiac implantable electronic devices in patients with persistent left superior vena cava—A single center experience
- Authors:
- Ghazzal, Bahjat
Sabayon, Dean
Kiani, Soroosh
Leon, Angel R.
Delurgio, David
Patel, Anshul M.
Lloyd, Michael S.
Westerman, Stacy
Shah, Anand
Merchant, Faisal M.
El‐Chami, Mikhael F. - Abstract:
- Abstract: Background: There are limited data on cardiac implantable electronic device implantation (CIED) in patients with persistent left superior vena cava (PLSVC). Objective: To describe the outcomes of implanting CIEDs with a focus on cardiac resynchronization therapy (CRT) in patients with PLSVC. Methods: We identified all patients with a PLSVC that underwent CIED implantation from December 2008 until February 2019 at our institution by querying the electronic medical record (n = 34). We then identified controls in a 3:1 fashion (n = 102) by matching on device type (CRT vs non‐CRT). Procedure success, complications, fluoroscopy and procedural time were recorded. Outcomes were compared using a two‐way analysis of variance test and conditional regression modeling for continuous and categorical variables, respectively. Results: A total of 34 patients with PLSVC underwent 38 procedures. Four patients underwent dual chamber system implantation followed by a subsequent upgrade to CRT. Thirteen patients underwent CRT implantation: one was implanted via the right subclavian while the rest were implanted via the PLSVC. Left ventricular ( P = .06). Procedure and fluoroscopy times were significantly higher in the PLSVC as compared with the control group (97.7 vs 66.1 minute, P < .001 and 18.1 minute vs 8.7 minutes, P = .005, respectively). Conclusion: CIED implant in patients with PLSVC is feasible but technically more challenging and appears to be associated with higher riskAbstract: Background: There are limited data on cardiac implantable electronic device implantation (CIED) in patients with persistent left superior vena cava (PLSVC). Objective: To describe the outcomes of implanting CIEDs with a focus on cardiac resynchronization therapy (CRT) in patients with PLSVC. Methods: We identified all patients with a PLSVC that underwent CIED implantation from December 2008 until February 2019 at our institution by querying the electronic medical record (n = 34). We then identified controls in a 3:1 fashion (n = 102) by matching on device type (CRT vs non‐CRT). Procedure success, complications, fluoroscopy and procedural time were recorded. Outcomes were compared using a two‐way analysis of variance test and conditional regression modeling for continuous and categorical variables, respectively. Results: A total of 34 patients with PLSVC underwent 38 procedures. Four patients underwent dual chamber system implantation followed by a subsequent upgrade to CRT. Thirteen patients underwent CRT implantation: one was implanted via the right subclavian while the rest were implanted via the PLSVC. Left ventricular ( P = .06). Procedure and fluoroscopy times were significantly higher in the PLSVC as compared with the control group (97.7 vs 66.1 minute, P < .001 and 18.1 minute vs 8.7 minutes, P = .005, respectively). Conclusion: CIED implant in patients with PLSVC is feasible but technically more challenging and appears to be associated with higher risk of right ventricular lead dislodgment. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 5(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 5(2020)
- Issue Display:
- Volume 31, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 5
- Issue Sort Value:
- 2020-0031-0005-0000
- Page Start:
- 1175
- Page End:
- 1181
- Publication Date:
- 2020-04-08
- Subjects:
- cardiac implantable electronic devices -- ICD -- left ventricular lead -- pacemakers -- persistent left superior vena cava
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14460 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13123.xml