Pre-bending a dynamic compression plate significantly alters strain distribution near the fracture plane in the mid-shaft femur. (May 2020)
- Record Type:
- Journal Article
- Title:
- Pre-bending a dynamic compression plate significantly alters strain distribution near the fracture plane in the mid-shaft femur. (May 2020)
- Main Title:
- Pre-bending a dynamic compression plate significantly alters strain distribution near the fracture plane in the mid-shaft femur
- Authors:
- Ristow, Jacob
Mead, Matthew
Cordeiro, Minal
Ostrander, James
Atkinson, Theresa
Atkinson, Patrick - Abstract:
- This study evaluated the effect of pre-bending dynamic compression plates on fracture site compression. Recommendations of 1 to 2 mm of pre-bend have been proposed, but there does not appear to be experimental data to confirm the optimal pre-bend magnitude. Dynamic compression plating was performed on the lateral convex surface of 18 femoral analogs to fixate a simulated mid-shaft fracture. Plates with 0 mm (flat plate), 1 mm, and 2 mm of pre-bend were evaluated for their production of compression by determining the strain magnitudes for 10 equal-sized zones across the anterior cortex at the osteotomy site using digital imaging correlation. The 0 and 1 mm plates produced significantly more compression at the near cortex (p = 0.001 and p = 0.003, respectively) than the 2 mm plate. However, the 0 and 1 mm plates also created visible diastasis at the far cortex, while the 2 mm plate exhibited compression across all zones. The strain magnitudes for the 0 mm (R 2 = 0.62) and 1 mm (R 2 = 0.86) plates linearly and significantly decreased from the region adjacent to the plate until a region 50%–60% across the analog diameter. In contrast, the 2 mm plate exhibited uniform strains across the osteotomy site. This study demonstrates that pre-bending a dynamic compression plate 2 mm prior to fixation on a convex lateral femur provides the most compression at the far cortex. It also produces more uniform compression across the fracture when compared to 0 and 1 mm of pre-bend.
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 234:Number 5(2020)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 234:Number 5(2020)
- Issue Display:
- Volume 234, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 234
- Issue:
- 5
- Issue Sort Value:
- 2020-0234-0005-0000
- Page Start:
- 478
- Page End:
- 485
- Publication Date:
- 2020-05
- Subjects:
- Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411920903875 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13105.xml