Hygrothermal performance of cold ventilated attics above different horizontal ceiling constructions: Full-scale test building. (July 2020)
- Record Type:
- Journal Article
- Title:
- Hygrothermal performance of cold ventilated attics above different horizontal ceiling constructions: Full-scale test building. (July 2020)
- Main Title:
- Hygrothermal performance of cold ventilated attics above different horizontal ceiling constructions: Full-scale test building
- Authors:
- Hansen, Thor
Møller, Eva B
Tvedebrink, Torben - Abstract:
- It is often assumed that reduced heat flux to a ventilated attic reduces the temperature and thereby increases the relative humidity. Consequently, the importance of having a tight air and vapour barrier in the ceiling becomes more important with increased insulation. Therefore, in Denmark, the recommendation is to have a tight vapour barrier when re-insulating ceilings against cold ventilated attics to a total of 150-mm insulation material. The recommendation is independent of the insulation material's hygroscopic properties or the indoor moisture level. The aim of this project was to test the relevance of the recommendation through testing in a full-scale test building (7 × 22 m) with a series of six different ceilings with or without a vapour barrier and variation in the insulation material comprising insulation thickness and its hygroscopic properties. The examination was performed with a controlled indoor climate after an European humidity classes 1–3 and a natural outdoor climate. The study showed very little differences in temperature and relative humidity in the cold ventilated attics, while the humidity class of the indoor climate significantly affects the absolute moisture content in the attic. However, the climate in the attic did not cause mould growth in the test sections, even for humidity class 3. Consequently, in the test building the thickness or hygroscopic properties of the insulation material did not have a significant effect on the moisture level inIt is often assumed that reduced heat flux to a ventilated attic reduces the temperature and thereby increases the relative humidity. Consequently, the importance of having a tight air and vapour barrier in the ceiling becomes more important with increased insulation. Therefore, in Denmark, the recommendation is to have a tight vapour barrier when re-insulating ceilings against cold ventilated attics to a total of 150-mm insulation material. The recommendation is independent of the insulation material's hygroscopic properties or the indoor moisture level. The aim of this project was to test the relevance of the recommendation through testing in a full-scale test building (7 × 22 m) with a series of six different ceilings with or without a vapour barrier and variation in the insulation material comprising insulation thickness and its hygroscopic properties. The examination was performed with a controlled indoor climate after an European humidity classes 1–3 and a natural outdoor climate. The study showed very little differences in temperature and relative humidity in the cold ventilated attics, while the humidity class of the indoor climate significantly affects the absolute moisture content in the attic. However, the climate in the attic did not cause mould growth in the test sections, even for humidity class 3. Consequently, in the test building the thickness or hygroscopic properties of the insulation material did not have a significant effect on the moisture level in attics and did not determine whether a vapour barrier should be installed. In this study with the given climate, a vapour barrier is unnecessary in well-ventilated attics if the ceiling is airtight. … (more)
- Is Part Of:
- Journal of building physics. Volume 44:Number 1(2020)
- Journal:
- Journal of building physics
- Issue:
- Volume 44:Number 1(2020)
- Issue Display:
- Volume 44, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2020-0044-0001-0000
- Page Start:
- 67
- Page End:
- 91
- Publication Date:
- 2020-07
- Subjects:
- Cold ventilated attics -- insulation material -- moisture -- vapour barrier -- mould growth
Buildings -- Environmental engineering -- Periodicals
Insulation (Heat) -- Periodicals
693.8 - Journal URLs:
- http://jen.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1744259119894028 ↗