Comparative Evaluation of Iodine-125 Radioactive Seed Localization and Wire Localization for Resection of Breast Lesions. Issue 4 (November 2017)
- Record Type:
- Journal Article
- Title:
- Comparative Evaluation of Iodine-125 Radioactive Seed Localization and Wire Localization for Resection of Breast Lesions. Issue 4 (November 2017)
- Main Title:
- Comparative Evaluation of Iodine-125 Radioactive Seed Localization and Wire Localization for Resection of Breast Lesions
- Authors:
- Tran, Vi Thuy
David, Julie
Patocskai, Erica
Zummo-Soucy, Mathieu
Younan, Rami
Lalonde, Lucie
Labelle, Maude
El Khoury, Mona
Robidoux, André
Trop, Isabelle - Abstract:
- Purpose: Radioactive seed localization (RSL) uses a titanium seed labeled with iodine-125 energy for surgery of nonpalpable breast lesions. RSL facilitates radiology–surgery scheduling and allows for improved oncoplasty compared with wire localization (WL). The purpose of this work was to compare the 2 techniques. Methods: We performed a retrospective study of all breast lesions operated with RSL between February 2013 and March 2015 at our university institution, and compared with an equivalent number of surgeries performed with a single WL. Imaging and pathology reports were reviewed for information on guidance mode, accuracy of targeting, nature of excised lesion, size and volume of surgical specimen, status of margins, and reinterventions. Results: A total of 254 lesions (247 women) were excised with RSL and compared with 257 lesions (244 women) whose surgery was guided by WL. Both groups were comparable in lesion pathology, guidance mode for RSL or WL positioning, and accuracy of targeting (98% correct). Mean delay between biopsy and surgery was 84 days for RSL versus 103 after WL ( P = .04). No differences were noted after RSL or WL for surgical specimen mean weight, largest diameter, and volume excised. For malignancies, the rate of positive margins was comparable (2.8%-3%), with 5 of 10 women in the RSL group who underwent a second surgery displaying residual malignancy compared with 3 of 9 women in the WL group. Conclusions: RSL is safe and accurate, and hasPurpose: Radioactive seed localization (RSL) uses a titanium seed labeled with iodine-125 energy for surgery of nonpalpable breast lesions. RSL facilitates radiology–surgery scheduling and allows for improved oncoplasty compared with wire localization (WL). The purpose of this work was to compare the 2 techniques. Methods: We performed a retrospective study of all breast lesions operated with RSL between February 2013 and March 2015 at our university institution, and compared with an equivalent number of surgeries performed with a single WL. Imaging and pathology reports were reviewed for information on guidance mode, accuracy of targeting, nature of excised lesion, size and volume of surgical specimen, status of margins, and reinterventions. Results: A total of 254 lesions (247 women) were excised with RSL and compared with 257 lesions (244 women) whose surgery was guided by WL. Both groups were comparable in lesion pathology, guidance mode for RSL or WL positioning, and accuracy of targeting (98% correct). Mean delay between biopsy and surgery was 84 days for RSL versus 103 after WL ( P = .04). No differences were noted after RSL or WL for surgical specimen mean weight, largest diameter, and volume excised. For malignancies, the rate of positive margins was comparable (2.8%-3%), with 5 of 10 women in the RSL group who underwent a second surgery displaying residual malignancy compared with 3 of 9 women in the WL group. Conclusions: RSL is safe and accurate, and has comparable surgical endpoints to WL. Because RSL offers flexible scheduling and facilitated oncoplasty, RSL may replace WL for resection of nonpalpable single breast lesions. … (more)
- Is Part Of:
- Canadian Association of Radiologists journal. Volume 68:Issue 4(2017)
- Journal:
- Canadian Association of Radiologists journal
- Issue:
- Volume 68:Issue 4(2017)
- Issue Display:
- Volume 68, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 68
- Issue:
- 4
- Issue Sort Value:
- 2017-0068-0004-0000
- Page Start:
- 447
- Page End:
- 455
- Publication Date:
- 2017-11
- Subjects:
- Conservative breast surgery -- Radioactive seed localization -- Wire localization
Radiology, Medical -- Periodicals
Radiology, Medical -- Canada -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/10153 ↗
http://www.carjonline.org ↗
https://journals.sagepub.com/home/caj ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/journaldescription.cws_home/718496/description#description ↗ - DOI:
- 10.1016/j.carj.2017.04.006 ↗
- Languages:
- English
- ISSNs:
- 0846-5371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4722.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13070.xml