Inter-leg systolic blood pressure difference predicts cardiovascular events and mortality in incident hemodialysis patients. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- Inter-leg systolic blood pressure difference predicts cardiovascular events and mortality in incident hemodialysis patients. Issue 4 (April 2020)
- Main Title:
- Inter-leg systolic blood pressure difference predicts cardiovascular events and mortality in incident hemodialysis patients
- Authors:
- Kato, Sawako
Lindholm, Bengt
Qureshi, Abdul Rashid
Mukai, Hideyuki
Yuzawa, Yukio
Maruyama, Shoichi - Abstract:
- Background: High inter-arm blood pressure difference, a marker of vascular disease, may be difficult to assess in hemodialysis patients with arm arteriovenous fistulae. We investigated if high inter-leg systolic blood pressure difference associates with cardiovascular events and increased mortality in hemodialysis patients. Methods: Among 118 incident Japanese dialysis patients, bilateral leg blood pressure, arm blood pressure, brachial–ankle pulse wave velocity, and ankle–brachial index were measured, and the relative risk associated with inter-leg systolic blood pressure difference and other indices of vascular status was analyzed. Results: During follow-up (median, 46 months), 18 deaths and 75 cardiovascular events occurred in 38 patients. Kaplan–Meier curves showed that higher inter-leg systolic blood pressure difference was associated with overall (log-rank 9.35, p = 0.002) and cardiovascular (log-rank 5.81, p = 0.02) mortality. The period from the start of dialysis therapy to the first cardiovascular event was shorter as inter-leg systolic blood pressure difference increased (log-rank 23.7, p < 0.0001). In Cox hazard models, inter-leg systolic blood pressure difference greater than median independently predicted deaths (relative risk, 3.8; 95% confidence interval, 1.3–13.9) and cardiovascular events (relative risk, 3.9; 95% confidence interval, 1.9–9.21) after adjustments for age, sex, nutritional status, and diabetes, whereas other indices were not related to theBackground: High inter-arm blood pressure difference, a marker of vascular disease, may be difficult to assess in hemodialysis patients with arm arteriovenous fistulae. We investigated if high inter-leg systolic blood pressure difference associates with cardiovascular events and increased mortality in hemodialysis patients. Methods: Among 118 incident Japanese dialysis patients, bilateral leg blood pressure, arm blood pressure, brachial–ankle pulse wave velocity, and ankle–brachial index were measured, and the relative risk associated with inter-leg systolic blood pressure difference and other indices of vascular status was analyzed. Results: During follow-up (median, 46 months), 18 deaths and 75 cardiovascular events occurred in 38 patients. Kaplan–Meier curves showed that higher inter-leg systolic blood pressure difference was associated with overall (log-rank 9.35, p = 0.002) and cardiovascular (log-rank 5.81, p = 0.02) mortality. The period from the start of dialysis therapy to the first cardiovascular event was shorter as inter-leg systolic blood pressure difference increased (log-rank 23.7, p < 0.0001). In Cox hazard models, inter-leg systolic blood pressure difference greater than median independently predicted deaths (relative risk, 3.8; 95% confidence interval, 1.3–13.9) and cardiovascular events (relative risk, 3.9; 95% confidence interval, 1.9–9.21) after adjustments for age, sex, nutritional status, and diabetes, whereas other indices were not related to the risks. For well-nourished, moderately malnourished, and severely malnourished patients, the cumulative number of cardiovascular events in the high–inter-leg systolic blood pressure difference patients were 4.96, 31.44, and 55.18 events per 100 patient-years. Conclusions: Higher inter-leg systolic blood pressure difference associated with increased risk of mortality and cardiovascular events suggesting that wider application of inter-leg systolic blood pressure difference measurements may be warranted in hemodialysis patients. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 43:Issue 4(2020)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 43:Issue 4(2020)
- Issue Display:
- Volume 43, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2020-0043-0004-0000
- Page Start:
- 217
- Page End:
- 224
- Publication Date:
- 2020-04
- Subjects:
- Cardiovascular event -- hemodialysis -- inter-leg systolic blood pressure difference -- mortality -- protein-energy wasting
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.1177/0391398819882703 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13060.xml