Multizone modelling of a hybrid ventilated high-rise building based on full-scale measurements for predictive control. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- Multizone modelling of a hybrid ventilated high-rise building based on full-scale measurements for predictive control. Issue 4 (April 2020)
- Main Title:
- Multizone modelling of a hybrid ventilated high-rise building based on full-scale measurements for predictive control
- Authors:
- Qi, Dahai
Cheng, Jun
Katal, Ali
Wang, Liangzhu (Leon)
Athienitis, Andreas - Other Names:
- Cao Shi-Jie guest-editor.
- Abstract:
- Hybrid ventilation is an effective approach to reduce cooling energy consumption by combining natural and mechanical ventilation. Previous studies of full-scale whole-building measurements of high-rise hybrid ventilation are quite limited due to the complexities of buildings and variable ambient conditions. As a result, validated and accurate whole-building simulations of hybrid ventilation often cannot be found in the literature. This paper reports a series of full-scale measurements of hybrid ventilation in a 17-storey high-rise building and associated whole-building simulations by 15-zone detailed and a 5-zone simplified multizone models. The paper is one of the first studies of using multizone models and real-world full-scale data and sharing key operational and performance experience and case studies of high-rise hybrid ventilation. Both the test data and the validated simulation models can be used for the comparison and validation of simulation models. The 5-zone simplified model developed from this study was able to model such a complex high-rise building by only a few zones, making possible the on-line model predictive control of a high-rise building. This was illustrated in this paper by an example of optimizing the uniformity of the hybrid ventilation on different floors by modifying inlet areas.
- Is Part Of:
- Indoor + built environment. Volume 29:Issue 4(2020)
- Journal:
- Indoor + built environment
- Issue:
- Volume 29:Issue 4(2020)
- Issue Display:
- Volume 29, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 29
- Issue:
- 4
- Issue Sort Value:
- 2020-0029-0004-0000
- Page Start:
- 496
- Page End:
- 507
- Publication Date:
- 2020-04
- Subjects:
- High-rise building -- Hybrid ventilation -- Multizone -- Full-scale -- Predictive control -- Whole building
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Buildings -- Environmental engineering -- Periodicals
Environmental health -- Periodicals
613.5 - Journal URLs:
- http://ibe.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org ↗
http://www.ingenta.com/isis/browsing/AllIssues/ingenta;jsessionid=2uxluqljhi7q.crescent?journal=pubinfobike://sage/ibe ↗ - DOI:
- 10.1177/1420326X19856405 ↗
- Languages:
- English
- ISSNs:
- 1420-326X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13047.xml