Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes. Issue 6 (27th September 2018)
- Record Type:
- Journal Article
- Title:
- Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes. Issue 6 (27th September 2018)
- Main Title:
- Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes
- Authors:
- Korkerdsup, Theerawat
Ngarmukos, Tachapong
Sungkanuparph, Somnuek
Phuphuakrat, Angsana - Abstract:
- Abstract: Background: Despite the long experience of cardiac implantable electronic device (CIED) implantation in Thailand, epidemiology of CIED infection in Thailand has never been studied. Methods: A retrospective cohort study was conducted at the cardiac referral center in Thailand to investigate incidence of CIED infection and causative organisms between October 2002 and December 2017. A matched case‐control study was performed to determine the factors associated with CIED infection. Results: Incidence of CIED infection was 0.9% with a stable trend during the studied period. There were 54 episodes of CIED infection. The median (interquartile range) age of the patients was 67.5 (53.0‐75.0) years. A total of 29 (53.7%), 18 (33.3%), and 7 (13.0%) were permanent pacemaker, automatic implantable cardioverter‐defibrillator, and cardio‐resynchronization therapy‐related infection, respectively. Gram‐positive cocci were the most common organism (24 episodes, 44.4%). Gram‐negative bacilli were isolated in six episodes (11.1%). About 9.3% were polymicrobial and 35.2% were culture negative. Multivariate analysis showed that previous CIED infection and generator revision procedure were associated with CIED infection (odds ratio [OR] 48.56, 95% confidence interval [CI] 3.72‐633.62; P = 0.003 and OR 19.99, 95% CI 1.28‐333.24; P = 0.033 respectively). Forty (74.1%) cases were cured. Leaving device in situ was the only factor significantly associated with poor outcome (OR 11.40, 95%Abstract: Background: Despite the long experience of cardiac implantable electronic device (CIED) implantation in Thailand, epidemiology of CIED infection in Thailand has never been studied. Methods: A retrospective cohort study was conducted at the cardiac referral center in Thailand to investigate incidence of CIED infection and causative organisms between October 2002 and December 2017. A matched case‐control study was performed to determine the factors associated with CIED infection. Results: Incidence of CIED infection was 0.9% with a stable trend during the studied period. There were 54 episodes of CIED infection. The median (interquartile range) age of the patients was 67.5 (53.0‐75.0) years. A total of 29 (53.7%), 18 (33.3%), and 7 (13.0%) were permanent pacemaker, automatic implantable cardioverter‐defibrillator, and cardio‐resynchronization therapy‐related infection, respectively. Gram‐positive cocci were the most common organism (24 episodes, 44.4%). Gram‐negative bacilli were isolated in six episodes (11.1%). About 9.3% were polymicrobial and 35.2% were culture negative. Multivariate analysis showed that previous CIED infection and generator revision procedure were associated with CIED infection (odds ratio [OR] 48.56, 95% confidence interval [CI] 3.72‐633.62; P = 0.003 and OR 19.99, 95% CI 1.28‐333.24; P = 0.033 respectively). Forty (74.1%) cases were cured. Leaving device in situ was the only factor significantly associated with poor outcome (OR 11.40, 95% CI 1.52‐85.73; P = 0.018). Conclusions: In Thailand, while CIED implantation is rising, incidence of CIED infection is stable. Microbiology of CIED infection in Thailand is similar to western countries, albeit a higher proportion of negative culture. Previous CIED infection and generator revision procedure are associated with CIED infection. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 34:Issue 6(2018)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 34:Issue 6(2018)
- Issue Display:
- Volume 34, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 6
- Issue Sort Value:
- 2018-0034-0006-0000
- Page Start:
- 632
- Page End:
- 639
- Publication Date:
- 2018-09-27
- Subjects:
- cardiac implantable electronic device infection -- microbiology -- risk factors -- Thailand -- treatment outcome
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12123 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13067.xml