Influence of background suppression and retrospective realignment on free‐breathing renal perfusion measurement using pseudo‐continuous ASL. Issue 4 (25th November 2018)
- Record Type:
- Journal Article
- Title:
- Influence of background suppression and retrospective realignment on free‐breathing renal perfusion measurement using pseudo‐continuous ASL. Issue 4 (25th November 2018)
- Main Title:
- Influence of background suppression and retrospective realignment on free‐breathing renal perfusion measurement using pseudo‐continuous ASL
- Authors:
- Taso, Manuel
Guidon, Arnaud
Alsop, David C. - Abstract:
- Abstract : Purpose: To assess the influence of background suppression and retrospective realignment on physiological noise and image quality in free‐breathing renal pseudo‐continuous arterial spin labeling (pCASL). Methods: Ten subjects were scanned at 3T with a pCASL prepared single‐slice coronal acquisition through the kidneys under free breathing. Multiple acquisitions were performed with various levels of residual background signal based on optimization of pulse timings to achieve specific background suppression levels (<2%, <5%, <10%, <20%). A retrospective non‐rigid motion‐correction strategy was also implemented. Results: Decreasing level of residual background signal was associated with higher temporal SNR. The retrospective motion‐correction provided an additional but not statistically significant improvement in tSNR. The highest image quality was obtained with the lowest level of residual background signal accompanied by the retrospective motion‐correction, although no significant difference in quantitative renal blood‐flow could be observed. Conclusions: Renal perfusion measurement with ASL under free breathing is feasible and robust against physiological noise when using strong background suppression strategies. Finally, retrospective motion‐correction further improves image quality but cannot replace background suppression.
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 4(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 4(2019)
- Issue Display:
- Volume 81, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 4
- Issue Sort Value:
- 2019-0081-0004-0000
- Page Start:
- 2439
- Page End:
- 2449
- Publication Date:
- 2018-11-25
- Subjects:
- arterial spin labeling -- ASL -- background suppression -- kidney -- motion correction -- MRI -- perfusion -- physiological noise -- temporal SNR
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27575 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13049.xml