Fibreoptic‐guided tracheal intubation through i‐gel® and LMA® ProtectorTM supraglottic airway devices ‐ a randomised comparison. (22nd November 2018)
- Record Type:
- Journal Article
- Title:
- Fibreoptic‐guided tracheal intubation through i‐gel® and LMA® ProtectorTM supraglottic airway devices ‐ a randomised comparison. (22nd November 2018)
- Main Title:
- Fibreoptic‐guided tracheal intubation through i‐gel® and LMA® ProtectorTM supraglottic airway devices ‐ a randomised comparison
- Authors:
- Mendonca, C.
Tourville, C. C.
Jefferson, H.
Nowicka, A.
Patteril, M.
Athanassoglou, V. - Abstract:
- Summary: Fibreoptic‐guided tracheal intubation using a supraglottic airway device as a conduit is a technique that can be used in anticipated and unanticipated difficult airway management. Although the i‐gel ® supraglottic airway device has been examined for this purpose, the LMA ® Protector TM, a recently introduced second‐generation supraglottic airway device, has not been evaluated for this use in clinical trials. This prospective, randomised clinical trial compared fibreoptic‐guided tracheal intubation via i‐gel and LMA Protector supraglottic airway devices in two UK hospitals. Patients who were ASA physical status 1 or 2 and undergoing elective surgery requiring tracheal intubation were recruited to the study. A block randomisation list was generated for each study site. The primary outcome measure was time to successful tracheal intubation and secondary outcomes were tracheal intubation success rate, glottic view through flexible fibrescope, ease of tracheal intubation using operator visual analogue score, supraglottic airway device insertion time and insertion success rate. Ninety patients were randomly allocated to each device, and final data analysis was carried out for 92 patients in the i‐gel group and 86 patients in the LMA Protector group. Mean (SD) tracheal intubation time in the i‐gel and LMA Protector groups were 54.3 (13.8) s and 52.0 (13.0) s, respectively (p = 0.240). There were no significant differences in tracheal intubation success rate, glottic viewSummary: Fibreoptic‐guided tracheal intubation using a supraglottic airway device as a conduit is a technique that can be used in anticipated and unanticipated difficult airway management. Although the i‐gel ® supraglottic airway device has been examined for this purpose, the LMA ® Protector TM, a recently introduced second‐generation supraglottic airway device, has not been evaluated for this use in clinical trials. This prospective, randomised clinical trial compared fibreoptic‐guided tracheal intubation via i‐gel and LMA Protector supraglottic airway devices in two UK hospitals. Patients who were ASA physical status 1 or 2 and undergoing elective surgery requiring tracheal intubation were recruited to the study. A block randomisation list was generated for each study site. The primary outcome measure was time to successful tracheal intubation and secondary outcomes were tracheal intubation success rate, glottic view through flexible fibrescope, ease of tracheal intubation using operator visual analogue score, supraglottic airway device insertion time and insertion success rate. Ninety patients were randomly allocated to each device, and final data analysis was carried out for 92 patients in the i‐gel group and 86 patients in the LMA Protector group. Mean (SD) tracheal intubation time in the i‐gel and LMA Protector groups were 54.3 (13.8) s and 52.0 (13.0) s, respectively (p = 0.240). There were no significant differences in tracheal intubation success rate, glottic view and ease of tracheal intubation between the two groups. This study demonstrates that the LMA Protector supraglottic airway device is comparable to the i‐gel supraglottic airway device as a conduit for fibreoptic‐guided tracheal intubation. … (more)
- Is Part Of:
- Anaesthesia. Volume 74:Number 2(2019)
- Journal:
- Anaesthesia
- Issue:
- Volume 74:Number 2(2019)
- Issue Display:
- Volume 74, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 74
- Issue:
- 2
- Issue Sort Value:
- 2019-0074-0002-0000
- Page Start:
- 203
- Page End:
- 210
- Publication Date:
- 2018-11-22
- Subjects:
- airway management -- failed tracheal intubation -- fibreoptic tracheal intubation -- supraglottic airway
Anesthesia -- Periodicals
617.96 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.aagbi.org/publications ↗ - DOI:
- 10.1111/anae.14475 ↗
- Languages:
- English
- ISSNs:
- 0003-2409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13040.xml