Is the Cranial and Posterior Screw of the "Inverted Triangle" Configuration for Femoral Neck Fractures Safe?. Issue 7 (July 2019)
- Record Type:
- Journal Article
- Title:
- Is the Cranial and Posterior Screw of the "Inverted Triangle" Configuration for Femoral Neck Fractures Safe?. Issue 7 (July 2019)
- Main Title:
- Is the Cranial and Posterior Screw of the "Inverted Triangle" Configuration for Femoral Neck Fractures Safe?
- Authors:
- Hoffmann, Jacob C.
Kellam, James
Kumaravel, Manickam
Clark, Kurt
Routt, Milton L. "Chip"
Gary, Joshua L. - Abstract:
- Abstract : Objectives: To determine the frequency where a posterior and cranial screw in a femoral neck that appeared contained on fluoroscopy violates the cortex. Methods: Ten specimens including the hemipelvis with the proximal femur were obtained from unidentified embalmed specimens that were to be cremated after an institutional review board waiver was granted. Under fluoroscopy, the posterior and cranial screw of the inverted triangle configuration for the femoral neck was placed using standard technique with a cannulated 6.5-mm screw. Anterior–posterior and lateral images of the final screw placement were blinded to 2 orthopaedic traumatologists and 1 musculoskeletal radiologist who were asked to determine whether the screw radiographically breached the posterior and cranial cortex. Cadavers were stripped of soft tissues and inspected for screw perforation. Screws were grouped as contained, thread extrusion, or core extrusion. Results: Reviewers classified all 10 screws as radiographically contained within the femoral neck. Cadavers were inspected and found to show: 4 of 10 with core extrusion, 3 of 10 with thread extrusion, and 3 of 10 screws contained within the femoral neck. Conclusions: Seventy percent of screws that were judged to be radiographically contained had cortical breach near the area where the lateral epiphyseal vessels enter the femoral neck. We urge caution against placement of posterior-cranial implants with fluoroscopy alone even if they appearAbstract : Objectives: To determine the frequency where a posterior and cranial screw in a femoral neck that appeared contained on fluoroscopy violates the cortex. Methods: Ten specimens including the hemipelvis with the proximal femur were obtained from unidentified embalmed specimens that were to be cremated after an institutional review board waiver was granted. Under fluoroscopy, the posterior and cranial screw of the inverted triangle configuration for the femoral neck was placed using standard technique with a cannulated 6.5-mm screw. Anterior–posterior and lateral images of the final screw placement were blinded to 2 orthopaedic traumatologists and 1 musculoskeletal radiologist who were asked to determine whether the screw radiographically breached the posterior and cranial cortex. Cadavers were stripped of soft tissues and inspected for screw perforation. Screws were grouped as contained, thread extrusion, or core extrusion. Results: Reviewers classified all 10 screws as radiographically contained within the femoral neck. Cadavers were inspected and found to show: 4 of 10 with core extrusion, 3 of 10 with thread extrusion, and 3 of 10 screws contained within the femoral neck. Conclusions: Seventy percent of screws that were judged to be radiographically contained had cortical breach near the area where the lateral epiphyseal vessels enter the femoral neck. We urge caution against placement of posterior-cranial implants with fluoroscopy alone even if they appear radiographically contained. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 33:Issue 7(2019)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 33:Issue 7(2019)
- Issue Display:
- Volume 33, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 7
- Issue Sort Value:
- 2019-0033-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-07
- Subjects:
- femoral neck fractures -- posterior-cranial femoral neck cortex -- cannulated screw fixation -- avascular necrosis -- fixation failure
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001461 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13038.xml