Heat stress assessment during intermittent work under different environmental conditions and clothing combinations of effective wet bulb globe temperature (WBGT). Issue 7 (3rd July 2019)
- Record Type:
- Journal Article
- Title:
- Heat stress assessment during intermittent work under different environmental conditions and clothing combinations of effective wet bulb globe temperature (WBGT). Issue 7 (3rd July 2019)
- Main Title:
- Heat stress assessment during intermittent work under different environmental conditions and clothing combinations of effective wet bulb globe temperature (WBGT)
- Authors:
- Seo, Yongsuk
Powell, Jeffrey
Strauch, Amanda
Roberge, Raymond
Kenny, Glen P.
Kim, Jung-Hyun - Abstract:
- Abstract: This study examined whether different combinations of ambient temperature and relative humidity for the effective wet bulb globe temperature, in conjunction with two different levels of clothing adjustment factors, elicit a similar level of heat strain consistent with the current threshold limit value guidelines. Twelve healthy, physically active men performed four 15-min sessions of cycling at a fixed rate of metabolic heat production of 350 watts. Each trial was separated by a 15-min recovery period under four conditions: (1) Cotton coveralls + dry condition (WD: 45.5 °C dry-bulb, 15% relative humidity); (2) Cotton coveralls + humid condition (WH: 31 °C dry-bulb, 84% relative humidity); (3) Protective clothing + dry condition (PD: 30 °C dry-bulb, 15% relative humidity); and (4) Protective clothing + humid condition (PH: 20 °C dry-bulb, 80% relative humidity). Gloves (mining or chemical) and headgear (helmet or powered air-purifying respirator) were removed during recovery with hydration ad libitum . Rectal temperature (Tre), skin temperature (Tsk), physiological heat strain (PSI), perceptual heat strain (PeSI), and body heat content were calculated. At the end of the 2-hr trials, Tre remained below 38 °C and the magnitude of Tre elevation was not greater than 1 °C in all conditions (WD: 0.9, WH: 0.8, WH: 0.7, and PD: 0.6 °C). However, Tsk was significantly increased by approximately 2.1 ± 0.8 °C across all conditions (all p ≤ 0.001). The increase in Tsk was theAbstract: This study examined whether different combinations of ambient temperature and relative humidity for the effective wet bulb globe temperature, in conjunction with two different levels of clothing adjustment factors, elicit a similar level of heat strain consistent with the current threshold limit value guidelines. Twelve healthy, physically active men performed four 15-min sessions of cycling at a fixed rate of metabolic heat production of 350 watts. Each trial was separated by a 15-min recovery period under four conditions: (1) Cotton coveralls + dry condition (WD: 45.5 °C dry-bulb, 15% relative humidity); (2) Cotton coveralls + humid condition (WH: 31 °C dry-bulb, 84% relative humidity); (3) Protective clothing + dry condition (PD: 30 °C dry-bulb, 15% relative humidity); and (4) Protective clothing + humid condition (PH: 20 °C dry-bulb, 80% relative humidity). Gloves (mining or chemical) and headgear (helmet or powered air-purifying respirator) were removed during recovery with hydration ad libitum . Rectal temperature (Tre), skin temperature (Tsk), physiological heat strain (PSI), perceptual heat strain (PeSI), and body heat content were calculated. At the end of the 2-hr trials, Tre remained below 38 °C and the magnitude of Tre elevation was not greater than 1 °C in all conditions (WD: 0.9, WH: 0.8, WH: 0.7, and PD: 0.6 °C). However, Tsk was significantly increased by approximately 2.1 ± 0.8 °C across all conditions (all p ≤ 0.001). The increase in Tsk was the highest in WD followed by PD, WH, and PH conditions (all p ≤ 0.001). Although PSI and PeSI did not indicate severe heat strain during the 2-hr intermittent work period, PSI and PeSI were significantly increased over time (p ≤ 0.001). This study showed that core temperature and heat strain indices (PSI and PeSI) increased similarly across the four conditions. However, given that core temperature increased continuously during the work session, it is likely that the American Conference of Governmental Industrial Hygienist's TLV ® upper limit core temperature of 38.0 °C may be surpassed during extended work periods under all conditions. … (more)
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 16:Issue 7(2019)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 16:Issue 7(2019)
- Issue Display:
- Volume 16, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 16
- Issue:
- 7
- Issue Sort Value:
- 2019-0016-0007-0000
- Page Start:
- 467
- Page End:
- 476
- Publication Date:
- 2019-07-03
- Subjects:
- Heat stress -- intermittent work -- threshold limit values -- wet bulb globe temperature
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2019.1612523 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13029.xml