Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules. Issue 105 (August 2018)
- Record Type:
- Journal Article
- Title:
- Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules. Issue 105 (August 2018)
- Main Title:
- Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules
- Authors:
- Gu, Fen
Han, Lu
Yang, Xiao
Liu, Haijing
Li, Xiaoyu
Guo, Kai
Zhao, Zhen
Zhou, Xiaodong
Luo, Wen - Abstract:
- Abstract: Objective: To assess the feasibility of time-intensity curve (TIC) analysis of contrast-enhanced ultrasound (CEUS) in demonstrating features of benign and malignant thyroid nodules. Methods: CEUS images of 98 patients with 103 thyroid nodules were retrospectively analyzed. The final diagnosis was confirmed by histology after surgical excision, or cytology after fine needle aspiration (FNA). Among the benign nodules, which were confirmed using cytology and not surgically removed, those with a >50% cystic component that showed no changes for 1 year on follow-up US, were diagnosed as clinically benign nodules. Similarly, nodules with a <50% cystic component that were aspirated twice and showed no changes for 1 year on follow-up US were also regarded as clinically benign nodules. TIC parameters, including perfusion parameters of relative values (RV) of peak intensity (PI) (△PI), RV of rise time (△RT), RV of time to peak (△TTP), RV of maximum slope coefficient (MSC) of wash-in (△MSCWI ), RV of area under the rising curve (△AUCR ), clearance parameters of RV of area under the falling curve (△AUCF ), RV of MSC of washout (△MSCWO ), comprehensive parameters of RV of mean transit time (△MTT), and area under the falling curve (△AUCF ) were observed. Results: Compared with benign thyroid nodules, malignant nodules on TIC analysis of CEUS showed a lower △PI (119.73 (115.34, 129.7), −15.82 (−17.7, -4.31)), later △RT (−0.27 (−0.51, −0.2), 0.58 (−0.26, 0.65)) and △TTP (−0.52Abstract: Objective: To assess the feasibility of time-intensity curve (TIC) analysis of contrast-enhanced ultrasound (CEUS) in demonstrating features of benign and malignant thyroid nodules. Methods: CEUS images of 98 patients with 103 thyroid nodules were retrospectively analyzed. The final diagnosis was confirmed by histology after surgical excision, or cytology after fine needle aspiration (FNA). Among the benign nodules, which were confirmed using cytology and not surgically removed, those with a >50% cystic component that showed no changes for 1 year on follow-up US, were diagnosed as clinically benign nodules. Similarly, nodules with a <50% cystic component that were aspirated twice and showed no changes for 1 year on follow-up US were also regarded as clinically benign nodules. TIC parameters, including perfusion parameters of relative values (RV) of peak intensity (PI) (△PI), RV of rise time (△RT), RV of time to peak (△TTP), RV of maximum slope coefficient (MSC) of wash-in (△MSCWI ), RV of area under the rising curve (△AUCR ), clearance parameters of RV of area under the falling curve (△AUCF ), RV of MSC of washout (△MSCWO ), comprehensive parameters of RV of mean transit time (△MTT), and area under the falling curve (△AUCF ) were observed. Results: Compared with benign thyroid nodules, malignant nodules on TIC analysis of CEUS showed a lower △PI (119.73 (115.34, 129.7), −15.82 (−17.7, -4.31)), later △RT (−0.27 (−0.51, −0.2), 0.58 (−0.26, 0.65)) and △TTP (−0.52 (−0.55, −0.36), 0.69 (−0.04, 0.74)), gentler △MSCWI (6.18 (5.29, 7.44), −6.1 (−7.6, 2.14)), and smaller △AUCR (75.7 (56.95, 93.22), −88.43 (−108.89, −73.21)) in perfusion parameters; a smaller △AUCF (112.92 (87.77, 137.58), −75.55 (−105.28, −59.32)) in clearance parameters; and a smaller △AUC (181.7 (151.50, 219.06), −160.64 (−200.08, −144.11)), and an earlier △MTT (2.00 (1.85, 3.14), −2.09 (−2.48, −0.95)) in comprehensive parameters (P < 0.05). Multivariate analysis of RV of TIC parameters demonstrated that △MSCWI (OR = 0.112; 95% confidence interval [CI], 0.025–0.507) and △MTT (OR = 0.099; 95% CI, 0.028–0.346) were protective factors. Conclusions: TIC of CEUS is a very promising and valuable technique for differentiating benign and malignant thyroid nodules. … (more)
- Is Part Of:
- European journal of radiology. Issue 105(2018)
- Journal:
- European journal of radiology
- Issue:
- Issue 105(2018)
- Issue Display:
- Volume 105, Issue 105 (2018)
- Year:
- 2018
- Volume:
- 105
- Issue:
- 105
- Issue Sort Value:
- 2018-0105-0105-0000
- Page Start:
- 182
- Page End:
- 187
- Publication Date:
- 2018-08
- Subjects:
- TIC time-intensity curve -- CEUS contrast-enhanced ultrasound -- US ultrasound -- FNA fine needle aspiration -- RV relative values -- PI peak intensity -- RT rise time -- TTP time to peak -- MSCWI the maximum slope coefficient of wash-in -- MSCWO the maximum slope coefficient of washout -- AUC area under the curve -- AUCR area under the rising curve -- AUCF area under the falling curve -- MTT mean transit time -- △PI relative values of peak intensity -- △RT relative values of rise time -- △TTP relative values of time to peak -- △MSCWI relative values of the maximum slope coefficient of wash-in -- △MSCWO relative values of the maximum slope coefficient of washout -- △AUC relative values of area under the curve -- △AUCR relative values of area under the rising curve -- △AUCF relative values of area under the falling curve -- △MTT relative values of mean transit time
Thyroid nodule -- Contrast-enhanced ultrasound -- Time-intensity curve
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.05.013 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13019.xml