Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT. (July 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT. (July 2017)
- Main Title:
- Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT
- Authors:
- Vilches-Freixas, Gloria
Taasti, Vicki Trier
Muren, Ludvig Paul
Petersen, Jørgen Breede Baltzer
Létang, Jean Michel
Hansen, David Christoffer
Rit, Simon - Abstract:
- Abstract: Background and Purpose: Several strategies for estimating stopping power ratio (SPR) from dual-energy CT (DECT) have been proposed to improve accuracy of proton dose calculations. DECT methods can mainly be categorized into projection-based methods, where material decomposition is performed prior to image reconstruction, and image-based methods, where decomposition takes place after image reconstruction. With the advent of photon-counting and dual-layer technology, projection-based methods could be considered for SPR estimation. In this simulation-based study we compared the SPR accuracy of one projection- and three image-based DECT methods. Materials and Methods: X-ray CT projections of the female ICRP phantom were simulated using two different X-ray spectra with a realistic detector response and noise levels. ICRP slices at four different locations were selected. Reference SPR-maps were computed at 200 MeV. The SPR comparison was based on percentage deviation inside ROIs and relative range errors calculated with Radon transform of difference maps. Results: SPR root-mean-square errors (RMSE) over the selected ROIs were 0.54% for the projection-based method and 0.68%, 0.61% and 0.70% for the three image-based methods. The RMSE for the relative range errors were slightly smaller for the projection-based approach, but close to zero for all decomposition domains as positive and negative errors averaged out over the slice. Conclusions: SPR estimations with theAbstract: Background and Purpose: Several strategies for estimating stopping power ratio (SPR) from dual-energy CT (DECT) have been proposed to improve accuracy of proton dose calculations. DECT methods can mainly be categorized into projection-based methods, where material decomposition is performed prior to image reconstruction, and image-based methods, where decomposition takes place after image reconstruction. With the advent of photon-counting and dual-layer technology, projection-based methods could be considered for SPR estimation. In this simulation-based study we compared the SPR accuracy of one projection- and three image-based DECT methods. Materials and Methods: X-ray CT projections of the female ICRP phantom were simulated using two different X-ray spectra with a realistic detector response and noise levels. ICRP slices at four different locations were selected. Reference SPR-maps were computed at 200 MeV. The SPR comparison was based on percentage deviation inside ROIs and relative range errors calculated with Radon transform of difference maps. Results: SPR root-mean-square errors (RMSE) over the selected ROIs were 0.54% for the projection-based method and 0.68%, 0.61% and 0.70% for the three image-based methods. The RMSE for the relative range errors were slightly smaller for the projection-based approach, but close to zero for all decomposition domains as positive and negative errors averaged out over the slice. Conclusions: SPR estimations with the projection-based method produced slightly better results (though not statistically significant) than the three image-based methods used in this simulation-based study, therefore, with the advent of technological developments, projection-based methods could be considered for SPR estimation if projection data is available. … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 3(2017)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 3(2017)
- Issue Display:
- Volume 3, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 3
- Issue:
- 2017
- Issue Sort Value:
- 2017-0003-2017-0000
- Page Start:
- 28
- Page End:
- 36
- Publication Date:
- 2017-07
- Subjects:
- CT noise -- Dual-energy CT -- Proton stopping power ratio -- Range uncertainty -- Robustness
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2017.08.001 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13016.xml