Improvements to a method for determining leg length following total hip arthroplasty. (17th February 2020)
- Record Type:
- Journal Article
- Title:
- Improvements to a method for determining leg length following total hip arthroplasty. (17th February 2020)
- Main Title:
- Improvements to a method for determining leg length following total hip arthroplasty
- Authors:
- Wendler, Toni
Heilemann, Martin
Grunert, Ronny
Möbius, Robert
Schmidt, Michael
Schleifenbaum, Stefan
Prietzel, Torsten - Abstract:
- Abstract: Discrepancy in leg length does frequently occur as a side effect of total hip arthroplasty and may lead to reduced patient satisfaction as well as injury in the sequalae. It is consequently important to reduce leg length discrepancy where-ever technically possible. This may be achieved by recording precise intraoperative measurements and using different sized implanted components. The aim of the given study was to improve the accuracy of a previously validated optic measurement system (OMS) to reduce leg length discrepancy. This pre-existing OMS was first trialled and based on these preliminary findings developed further. Using this improved system, measurements were taken in models and cadavers. Inter observer reliability of the improved OMS was assessed. The system is introduced in the given technical feasibility study. Its accuracy was greater in the model setup (swivel joint: 772.7 ± 1.5 mm; ball joint: 770.0 ± 3.7 mm; reference: 772 mm) compared to the trial using cadaveric tissues (588.8 ± 5.7 mm; reference: 586 mm). Results of two examiners were similar. The third one measured significantly shorter values ( p =.011). The results of the measurements with the OMS indicate that a significant increase in accuracy ( p = 2.076× 10 − 6 ) has been achieved compared to the previously reported system, however, a further improvement to measurement accuracy is necessary for this to be applied clinically.
- Is Part Of:
- Journal of medical engineering & technology. Volume 44:Number 2(2020)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 44:Number 2(2020)
- Issue Display:
- Volume 44, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2020-0044-0002-0000
- Page Start:
- 69
- Page End:
- 75
- Publication Date:
- 2020-02-17
- Subjects:
- Leg length determination -- intraoperative measurements -- total hip arthroplasty -- optical measuring system
Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.1080/03091902.2020.1723727 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12981.xml