Oxidized regenerated cellulose for a clear thoracoscopic view: a single-centre randomized trial. (20th November 2019)
- Record Type:
- Journal Article
- Title:
- Oxidized regenerated cellulose for a clear thoracoscopic view: a single-centre randomized trial. (20th November 2019)
- Main Title:
- Oxidized regenerated cellulose for a clear thoracoscopic view: a single-centre randomized trial
- Authors:
- Shimizu, Nahoko
Tanaka, Yugo
Kuroda, Sanae
Nakamura, Hayate
Matsumoto, Gaku
Mitsui, Suguru
Sakai, Shuto
Minami, Kazuhiro
Doi, Takefumi
Hokka, Daisuke
Maniwa, Yoshimasa - Abstract:
- Abstract: : OBJECTIVES: During video-assisted thoracoscopic surgery (VATS), blood oozing from the surface of the access port wound can hamper the surgical view. Although this oozing is difficult to prevent, it can be decreased by placing a wound edge protector with oxidized regenerated cellulose (ORC) on the surface of the access port wound, thereby improving the surgical outcomes and safety of VATS. METHODS: We conducted a prospective, single-centre, open-label, randomized clinical trial to evaluate the operative outcomes of VATS when using the ORC (ORC group) compared with operative outcomes without using the ORC (non-ORC group). The primary end point was interruption of the operation as a result of blood oozing from the surface of the access port wound. The secondary end points were the other intraoperative and postoperative outcomes. RESULTS: A total of 108 patients were divided into the ORC group ( n = 54) and the non-ORC group ( n = 54). Compared with the non-ORC group, the ORC group had fewer patients with an interruption in the operation (11.1% vs 51.8%; P < 0.001), less need for wound haemostasis of the access ports during wound closure (44.4% vs 72.2%; P = 0.003), similar rates of postoperative deaths and complications and a tendency for shorter operation times (149.3 vs 168.8 min, respectively; P = 0.083). CONCLUSION: The use of an ORC sheet around a wound edge protector for haemostasis can ensure a clear view during VATS. Clinical trial registration number:Abstract: : OBJECTIVES: During video-assisted thoracoscopic surgery (VATS), blood oozing from the surface of the access port wound can hamper the surgical view. Although this oozing is difficult to prevent, it can be decreased by placing a wound edge protector with oxidized regenerated cellulose (ORC) on the surface of the access port wound, thereby improving the surgical outcomes and safety of VATS. METHODS: We conducted a prospective, single-centre, open-label, randomized clinical trial to evaluate the operative outcomes of VATS when using the ORC (ORC group) compared with operative outcomes without using the ORC (non-ORC group). The primary end point was interruption of the operation as a result of blood oozing from the surface of the access port wound. The secondary end points were the other intraoperative and postoperative outcomes. RESULTS: A total of 108 patients were divided into the ORC group ( n = 54) and the non-ORC group ( n = 54). Compared with the non-ORC group, the ORC group had fewer patients with an interruption in the operation (11.1% vs 51.8%; P < 0.001), less need for wound haemostasis of the access ports during wound closure (44.4% vs 72.2%; P = 0.003), similar rates of postoperative deaths and complications and a tendency for shorter operation times (149.3 vs 168.8 min, respectively; P = 0.083). CONCLUSION: The use of an ORC sheet around a wound edge protector for haemostasis can ensure a clear view during VATS. Clinical trial registration number: UMIN000031112. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 30:Number 3(2020)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 30:Number 3(2020)
- Issue Display:
- Volume 30, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2020-0030-0003-0000
- Page Start:
- 346
- Page End:
- 352
- Publication Date:
- 2019-11-20
- Subjects:
- Oxidized regenerated cellulose -- Video-assisted thoracoscopic surgery -- Randomized trial
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivz271 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: