Safety and effectiveness of a transaortic approach for TAVI: procedural and midterm outcomes of 265 consecutive patients in a single centre. (28th November 2019)
- Record Type:
- Journal Article
- Title:
- Safety and effectiveness of a transaortic approach for TAVI: procedural and midterm outcomes of 265 consecutive patients in a single centre. (28th November 2019)
- Main Title:
- Safety and effectiveness of a transaortic approach for TAVI: procedural and midterm outcomes of 265 consecutive patients in a single centre
- Authors:
- Romano, Mauro
Daprati, Andrea
Saitto, Guglielmo
Tizzano, Francesco
Le Houérou, Daniel
Donzeau-Gouge, Patrick
Farge, Arnaud
Lefèvre, Thierry
Hovasse, Thomas
Garatti, Andrea - Abstract:
- Abstract: : OBJECTIVES: Transcatheter aortic valve implantation with a transaortic approach (TAo-TAVI) is an alternative to transapical or femoral access. We studied the procedural and midterm efficacy and safety of TAo-TAVI with Edwards Sapien XT and Medtronic CoreValve devices. METHODS: Among 901 patients receiving TAVI since 2006, 265 consecutive patients underwent TAo-TAVI between January 2011 and September 2014. Procedural and midterm results were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: The mean age was 83 ± 5 years. Sapien XT and CoreValve were used in 191 (72.1%) and 74 (27.9%) patients, respectively. Full sternotomy made elective concomitant off-pump coronary artery bypass grafting possible in 38 patients (14.3%) with severe coronary artery disease unsuitable for percutaneous coronary intervention. The device success rate was 95.5%. Postprocedural paravalvular leak ≥2/4 was observed in 16 patients (6.4%). Emergency open chest surgery was required in 10 patients (3.8%) (3 aortic dissections, 3 valve embolizations, 2 LMCA occlusions, 1 aortic annulus rupture and 1 aortic rupture). Cerebrovascular accidents occurred in 3 patients (1.1%). Transfusions ≥4 units were required in 36 patients (13.6%). New pacemakers were implanted in 26 patients (9.8%). Thirty-day and 1-year mortality were 8.7% and 16.2%, respectively. Mean follow-up duration was 24 ± 6 months. At 3 years, freedom from all-cause death was 80% ± 4%. New York HeartAbstract: : OBJECTIVES: Transcatheter aortic valve implantation with a transaortic approach (TAo-TAVI) is an alternative to transapical or femoral access. We studied the procedural and midterm efficacy and safety of TAo-TAVI with Edwards Sapien XT and Medtronic CoreValve devices. METHODS: Among 901 patients receiving TAVI since 2006, 265 consecutive patients underwent TAo-TAVI between January 2011 and September 2014. Procedural and midterm results were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: The mean age was 83 ± 5 years. Sapien XT and CoreValve were used in 191 (72.1%) and 74 (27.9%) patients, respectively. Full sternotomy made elective concomitant off-pump coronary artery bypass grafting possible in 38 patients (14.3%) with severe coronary artery disease unsuitable for percutaneous coronary intervention. The device success rate was 95.5%. Postprocedural paravalvular leak ≥2/4 was observed in 16 patients (6.4%). Emergency open chest surgery was required in 10 patients (3.8%) (3 aortic dissections, 3 valve embolizations, 2 LMCA occlusions, 1 aortic annulus rupture and 1 aortic rupture). Cerebrovascular accidents occurred in 3 patients (1.1%). Transfusions ≥4 units were required in 36 patients (13.6%). New pacemakers were implanted in 26 patients (9.8%). Thirty-day and 1-year mortality were 8.7% and 16.2%, respectively. Mean follow-up duration was 24 ± 6 months. At 3 years, freedom from all-cause death was 80% ± 4%. New York Heart Association class <III included 81% ( n = 172) of patients alive and without prosthetic echocardiographic dysfunction at follow-up (mean gradient 10.5 ± 5.6 mmHg). CONCLUSION: The TAo-TAVI approach confirms its safety and effectiveness with satisfactory procedural and midterm outcomes with both currently available devices. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 30:Number 3(2020)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 30:Number 3(2020)
- Issue Display:
- Volume 30, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2020-0030-0003-0000
- Page Start:
- 400
- Page End:
- 407
- Publication Date:
- 2019-11-28
- Subjects:
- Transcatheter aortic valve -- Transaortic transcatheter aortic valve -- Transaortic approach for transcatheter aortic valve implantation -- Alternative access route for transcatheter aortic valve
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivz269 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12991.xml