In vitro study of trileaflet polytetrafluoroethylene conduit and its valve-in-valve transformation. (3rd January 2020)
- Record Type:
- Journal Article
- Title:
- In vitro study of trileaflet polytetrafluoroethylene conduit and its valve-in-valve transformation. (3rd January 2020)
- Main Title:
- In vitro study of trileaflet polytetrafluoroethylene conduit and its valve-in-valve transformation
- Authors:
- Chang, Te-I
Hsu, Kang-Hong
Luo, Chi-Wen
Yen, Jen-Hong
Lu, Po-Chien
Chang, Chung-I - Abstract:
- Abstract: : OBJECTIVES: Handmade trileaflet expanded polytetrafluoroethylene valved conduit developed using the flip-over method has been tailored for pulmonary valve reconstruction with satisfactory outcomes. We investigated the in vitro performance of the valve design in a mock circulatory system with various conduit sizes. In our study, the design was transformed into a transcatheter stent graft system which could fit in original valved conduits in a valve-in-valve fashion. METHODS: Five different sizes of valved polytetrafluoroethylene vascular grafts (16, 18, 20, 22 and 24 mm) were mounted onto a mock circulatory system with a prism window for direct leaflets motion observation. Transvalvular pressure gradients were recorded using pressure transducers. Mean and instant flows were determined via a rotameter and a flowmeter. Similar flip-over trileaflet valve design was then carried out in 3 available stent graft sizes (23, 26 and 28.5 mm, Gore aortic extender), which were deployed inside the valved conduits. RESULTS: Peak pressure gradient across 5 different sized graft valves, in their appropriate flow setting (2.0, 2.5 and 5.0 l/min), ranged from 4.7 to 13.2 mmHg. No significant valve regurgitation was noted (regurgitant fraction: 1.6–4.9%) in all valve sizes and combinations. Three sizes of the trileaflet-valved stent grafts were implanted in the 4 sizes of valved conduits except for the 16-mm conduit. Peak pressure gradient increase after valved-stentAbstract: : OBJECTIVES: Handmade trileaflet expanded polytetrafluoroethylene valved conduit developed using the flip-over method has been tailored for pulmonary valve reconstruction with satisfactory outcomes. We investigated the in vitro performance of the valve design in a mock circulatory system with various conduit sizes. In our study, the design was transformed into a transcatheter stent graft system which could fit in original valved conduits in a valve-in-valve fashion. METHODS: Five different sizes of valved polytetrafluoroethylene vascular grafts (16, 18, 20, 22 and 24 mm) were mounted onto a mock circulatory system with a prism window for direct leaflets motion observation. Transvalvular pressure gradients were recorded using pressure transducers. Mean and instant flows were determined via a rotameter and a flowmeter. Similar flip-over trileaflet valve design was then carried out in 3 available stent graft sizes (23, 26 and 28.5 mm, Gore aortic extender), which were deployed inside the valved conduits. RESULTS: Peak pressure gradient across 5 different sized graft valves, in their appropriate flow setting (2.0, 2.5 and 5.0 l/min), ranged from 4.7 to 13.2 mmHg. No significant valve regurgitation was noted (regurgitant fraction: 1.6–4.9%) in all valve sizes and combinations. Three sizes of the trileaflet-valved stent grafts were implanted in the 4 sizes of valved conduits except for the 16-mm conduit. Peak pressure gradient increase after valved-stent graft-in-valved-conduit setting was <10 mmHg in all 4 conduits. CONCLUSIONS: The study showed excellent in vitro performance of trileaflet polytetrafluoroethylene valved conduits. Its valved stent graft transformation provided data which may serve as a reference for transcatheter valve-in-valve research in the future. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 30:Number 3(2020)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 30:Number 3(2020)
- Issue Display:
- Volume 30, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2020-0030-0003-0000
- Page Start:
- 408
- Page End:
- 416
- Publication Date:
- 2020-01-03
- Subjects:
- Handmade trileaflet expanded polytetrafluoroethylene valved conduit -- Trileaflet expanded polytetrafluoroethylene valved stent graft -- Extended polytetrafluoroethylene valve -- Valve-in-valve -- Pulmonary valve replacement
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivz274 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12991.xml