The hospital results and 1-year outcomes of transcatheter aortic valve-in-valve procedures and transcatheter aortic valve implantations in the native valves: the results from the Swiss-TAVI Registry. (27th January 2019)
- Record Type:
- Journal Article
- Title:
- The hospital results and 1-year outcomes of transcatheter aortic valve-in-valve procedures and transcatheter aortic valve implantations in the native valves: the results from the Swiss-TAVI Registry. (27th January 2019)
- Main Title:
- The hospital results and 1-year outcomes of transcatheter aortic valve-in-valve procedures and transcatheter aortic valve implantations in the native valves: the results from the Swiss-TAVI Registry
- Authors:
- Ferrari, Enrico
Stortecky, Stefan
Heg, Dik
Muller, Olivier
Nietlispach, Fabian
Tueller, David
Toggweiler, Stefan
Noble, Stéphane
Maisano, Francesco
Roffi, Marco
Jeger, Raban
Grünenfelder, Jürg
Huber, Christoph
Windecker, Stephan
Wenaweser, Peter - Abstract:
- Abstract: OBJECTIVES: The SwissTAVI Registry includes all consecutive patients undergoing transcatheter aortic valve implantation (TAVI) and valve-in-valve (VinV) procedures for a failed bioprosthesis in Switzerland. We report the real world, all-comers, 30-day and 1-year outcomes of patients undergoing VinV and standard TAVI procedures. METHODS: Prospectively collected data from the 2 groups (VinV and standard TAVI patients) were retrospectively analysed. In an adjusted analysis, in-hospital and 1-year outcomes of VinV patients were compared with those of patients undergoing TAVI for native aortic valve disease in the same registry. A subanalysis of VinV procedures in stenotic or regurgitant bioprosthesis was also performed. RESULTS: Between February 2011 and December 2016, 4599 and 157 consecutive patients underwent TAVI in native aortic valves and VinV procedures in degenerate bioprosthesis, respectively. VinV patients were younger (78 ± 9.1 years vs 82.2 ± 6.3 years; P < 0.001) but at a higher risk for surgery (the logistic EuroSCORE: 28.48 ± 15.3% vs 18.2 ± 13.6%; P < 0.001; the Society of Thoracic Surgery (STS) score: 6.4 ± 5% vs 5.5 ± 4.3%; P = 0.008). Valve predilatation was less frequently performed during VinV procedures (22.9% vs 69.1%; P < 0.001), and the hospital stay was shorter after VinV procedure (8.46 ± 4.2 days vs 9.83 ± 6 days; P = 0.005). VinV patients showed higher predischarge transvalvular mean gradients (14.14 ± 7.9 mmHg vs 8.42 ± 5.0 mmHg; PAbstract: OBJECTIVES: The SwissTAVI Registry includes all consecutive patients undergoing transcatheter aortic valve implantation (TAVI) and valve-in-valve (VinV) procedures for a failed bioprosthesis in Switzerland. We report the real world, all-comers, 30-day and 1-year outcomes of patients undergoing VinV and standard TAVI procedures. METHODS: Prospectively collected data from the 2 groups (VinV and standard TAVI patients) were retrospectively analysed. In an adjusted analysis, in-hospital and 1-year outcomes of VinV patients were compared with those of patients undergoing TAVI for native aortic valve disease in the same registry. A subanalysis of VinV procedures in stenotic or regurgitant bioprosthesis was also performed. RESULTS: Between February 2011 and December 2016, 4599 and 157 consecutive patients underwent TAVI in native aortic valves and VinV procedures in degenerate bioprosthesis, respectively. VinV patients were younger (78 ± 9.1 years vs 82.2 ± 6.3 years; P < 0.001) but at a higher risk for surgery (the logistic EuroSCORE: 28.48 ± 15.3% vs 18.2 ± 13.6%; P < 0.001; the Society of Thoracic Surgery (STS) score: 6.4 ± 5% vs 5.5 ± 4.3%; P = 0.008). Valve predilatation was less frequently performed during VinV procedures (22.9% vs 69.1%; P < 0.001), and the hospital stay was shorter after VinV procedure (8.46 ± 4.2 days vs 9.83 ± 6 days; P = 0.005). VinV patients showed higher predischarge transvalvular mean gradients (14.14 ± 7.9 mmHg vs 8.42 ± 5.0 mmHg; P < 0.001), smaller mean valve surface area (1.54 ± 0.7 cm 2 vs 1.83 ± 0.5 cm 2 ; P < 0.001) and a lower risk of moderate/severe paravalvular leak (1.3% vs 5%). Post-procedural kidney injury (1.3% vs 4.8%; P = 0.06) and new pacemakers for conduction abnormalities (3.3% vs 18.5%; P < 0.001) were higher after TAVI. All-cause mortality and cardiovascular mortality at 30 days were similar between the 2 groups (1.9% vs 3.8%; P = 0.242 and 1.9% vs 3.4%; P = 0.321), whereas after 1 year, all-cause mortality was lower for VinV patients (6.8% vs 13%; P = 0.035). The bioprosthetic valve size correlated inversely with postoperative gradients after VinV procedures. CONCLUSIONS: VinV aortic procedures showed favourable 30-day and 1-year clinical outcomes compared with TAVI procedures for the native aortic valve disease. Despite higher transvalvular mean gradients following VinV implants, this appears not to impact the early clinical outcomes. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 56:Number 1(2019)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 56:Number 1(2019)
- Issue Display:
- Volume 56, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 56
- Issue:
- 1
- Issue Sort Value:
- 2019-0056-0001-0000
- Page Start:
- 55
- Page End:
- 63
- Publication Date:
- 2019-01-27
- Subjects:
- Transcatheter aortic valve implantation -- Bioprosthetic aortic valve -- Valve-in-valve procedure
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezy471 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12982.xml