The effect different substrates have on the trueness and precision of eight different intraoral scanners. Issue 2 (30th September 2019)
- Record Type:
- Journal Article
- Title:
- The effect different substrates have on the trueness and precision of eight different intraoral scanners. Issue 2 (30th September 2019)
- Main Title:
- The effect different substrates have on the trueness and precision of eight different intraoral scanners
- Authors:
- Dutton, Ethan
Ludlow, Mark
Mennito, Anthony
Kelly, Abigail
Evans, Zachary
Culp, Alexander
Kessler, Raymond
Renne, Walter - Abstract:
- Abstract: Objective: This in vitro study compares the newest generation of intraoral scanners to their older counterparts, and tests whether material substrates affect the trueness and precision of intraoral scanners (IOS). Material and methods: A custom model, used as the reference standard, was fabricated with teeth composed of different dental materials. The reference standard scan was obtained using a three‐dimensional (3D) optical scanner, the ATOS III. Experimental scans were obtained using eight different IOS, operated by experienced clinicians, using the manufacturer's recommended scanning strategy. A comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. Results: For all scanners tested, except Trios3, the substrate does influence the trueness and precision of the scan. Furthermore, differences exist when comparing the same substrate across different scanners with some of the latest generation scanners clearly leaping ahead of the older generation regarding both trueness and precision. Conclusions: Substrate type affects the trueness and precision of a scan. Active Triangulation scanners are more sensitive to substrate differences than their parallel confocal counterparts. Some scanners scan certain substrates better, but in general the new generation of scanners outperforms the old, across all substrates. Clinical significance: The substrates being scanned play an import role in the truenessAbstract: Objective: This in vitro study compares the newest generation of intraoral scanners to their older counterparts, and tests whether material substrates affect the trueness and precision of intraoral scanners (IOS). Material and methods: A custom model, used as the reference standard, was fabricated with teeth composed of different dental materials. The reference standard scan was obtained using a three‐dimensional (3D) optical scanner, the ATOS III. Experimental scans were obtained using eight different IOS, operated by experienced clinicians, using the manufacturer's recommended scanning strategy. A comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. Results: For all scanners tested, except Trios3, the substrate does influence the trueness and precision of the scan. Furthermore, differences exist when comparing the same substrate across different scanners with some of the latest generation scanners clearly leaping ahead of the older generation regarding both trueness and precision. Conclusions: Substrate type affects the trueness and precision of a scan. Active Triangulation scanners are more sensitive to substrate differences than their parallel confocal counterparts. Some scanners scan certain substrates better, but in general the new generation of scanners outperforms the old, across all substrates. Clinical significance: The substrates being scanned play an import role in the trueness and precision of the 3D model. The new generation of scanners is remarkably accurate across all substrates and for complete‐arch scanning. … (more)
- Is Part Of:
- Journal of esthetic and restorative dentistry. Volume 32:Issue 2(2020)
- Journal:
- Journal of esthetic and restorative dentistry
- Issue:
- Volume 32:Issue 2(2020)
- Issue Display:
- Volume 32, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2020-0032-0002-0000
- Page Start:
- 204
- Page End:
- 218
- Publication Date:
- 2019-09-30
- Subjects:
- accuracy -- dental materials -- digital dentistry -- intraoral scanner -- precision
Prosthodontics -- Periodicals
617.6 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jerd.12528 ↗
- Languages:
- English
- ISSNs:
- 1496-4155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4979.554000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12990.xml