Transcutaneous blood gas monitoring among neonatal intensive care units in Japan. Issue 2 (16th February 2020)
- Record Type:
- Journal Article
- Title:
- Transcutaneous blood gas monitoring among neonatal intensive care units in Japan. Issue 2 (16th February 2020)
- Main Title:
- Transcutaneous blood gas monitoring among neonatal intensive care units in Japan
- Authors:
- Ochiai, Masayuki
Kurata, Hiroaki
Inoue, Hirosuke
Ichiyama, Masako
Fujiyoshi, Junko
Watabe, Shinichi
Hiroma, Takehiko
Nakamura, Tomohiko
Ohga, Shouichi - Abstract:
- Abstract: Background: This study aimed to investigate the utility of transcutaneous (tc) measurements of partial pressure of oxygen (tcPO2 ) and carbon dioxide (tcPCO2 ) monitoring in neonatal intensive care units (NICUs) in Japan. Methods: At the end of 2016, we sent a survey questionnaire on tc monitoring to all 106 NICUs registered with the Japanese Neonatologist Association. The questions included usage, subjects, methods, management, and the practical usefulness of tc monitoring. Results: The questionnaire was returned by 69 NICUs (65.1% of response rate). Seventeen institutions (24.6%) measured both tcPCO2 and tcPO2, and 42 (60.9%) measured tcPCO2 alone. Transcutaneous PCO2 or tcPO2 monitoring was applied for "pre‐viable" infants born at 22–23 weeks' gestational age (18.6% vs 23.5%), and infants of <500 g birthweight (30.5% vs 17.6%). The tcPCO2 and tcPO2 monitoring was started at birth in 49.2% and 70.6% of the newborn infants, respectively. The temperature of the sensor was set at <38°C for tcPCO2 in 54.3% and >42°C for tcPO2 in 58.9% of NICUs. The accuracy for tcPO2 was rated as good in 35.3% or moderate in 64.7%, of institutions but or for tcPCO2 as 1.7% or 93.2%of institutions, respectively. Conclusion: Transcutaneous monitoring was widely, but limitedly, used for preterm infants. The lower temperature of the tcPCO2 sensor compared to that reported in other developed countries might compromise the accuracy but increase the feasibility of tc monitoring in Japan.
- Is Part Of:
- Pediatrics international. Volume 62:Issue 2(2020)
- Journal:
- Pediatrics international
- Issue:
- Volume 62:Issue 2(2020)
- Issue Display:
- Volume 62, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 62
- Issue:
- 2
- Issue Sort Value:
- 2020-0062-0002-0000
- Page Start:
- 169
- Page End:
- 174
- Publication Date:
- 2020-02-16
- Subjects:
- arterial puncture -- end‐tidal CO2 low birthweight -- preterm birth -- pulse oximetry
Pediatrics -- Periodicals
618.92 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-200X/issues. Subscription to online journal required for access to full text. ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ped.14107 ↗
- Languages:
- English
- ISSNs:
- 1328-8067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.655800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12989.xml