Aortic valve area using computed tomography‐derived correction factor to improve the validity of left ventricular outflow tract measurements. Issue 2 (31st January 2020)
- Record Type:
- Journal Article
- Title:
- Aortic valve area using computed tomography‐derived correction factor to improve the validity of left ventricular outflow tract measurements. Issue 2 (31st January 2020)
- Main Title:
- Aortic valve area using computed tomography‐derived correction factor to improve the validity of left ventricular outflow tract measurements
- Authors:
- Alskaf, Ebraham
Gupta, Tarun
Kardos, Attila - Abstract:
- Abstract: Aims: Given the inherent inaccuracies stemming from the assumption that the left ventricular outflow tract (LVOT) is circular, this study aimed to improve the accuracy of transthoracic echocardiography (TTE)‐based aortic valve area (AVA) calculation using continuity equation (CE) by introducing a correction factor (CF) derived from multidetector computed tomography angiography (MDCTA) images and validate it in aortic stenosis (AS) patients. Methods and Results: This retrospective study used MDCTA images of 400 patients for modeling and 403 TTE dataset for validation. Echocardiographic parasternal long‐axis view was modeled using MDCTA, and LVOT diameter (D1) was measured. Direct planimetry of LVOT area was performed and subsequently converted into a theoretical circle. The assumed circle (D2) diameter was derived, and D2/D1 was calculated and termed as the CF. The CF was 1.13, and it improved the agreement between MDCTA‐ and TTE‐derived LVOT areas and correlation between AVA and peak velocity, mean pressure gradient, and velocity ratio. In discordant subgroups of severe AS, the CF reclassified patients to moderate AS in 40% in the low flow (LF), low gradient (LG), and low ejection fraction (EF) group; 53% in the LF, LG, and normal EF group; and 68% in the LF, high gradient, and normal EF group. Conclusions: CF of 1.13 derived from MDCTA improved the accuracy of TTE‐derived LVOT area and AVA and improved correlation with hemodynamic variables in AS patients.Abstract: Aims: Given the inherent inaccuracies stemming from the assumption that the left ventricular outflow tract (LVOT) is circular, this study aimed to improve the accuracy of transthoracic echocardiography (TTE)‐based aortic valve area (AVA) calculation using continuity equation (CE) by introducing a correction factor (CF) derived from multidetector computed tomography angiography (MDCTA) images and validate it in aortic stenosis (AS) patients. Methods and Results: This retrospective study used MDCTA images of 400 patients for modeling and 403 TTE dataset for validation. Echocardiographic parasternal long‐axis view was modeled using MDCTA, and LVOT diameter (D1) was measured. Direct planimetry of LVOT area was performed and subsequently converted into a theoretical circle. The assumed circle (D2) diameter was derived, and D2/D1 was calculated and termed as the CF. The CF was 1.13, and it improved the agreement between MDCTA‐ and TTE‐derived LVOT areas and correlation between AVA and peak velocity, mean pressure gradient, and velocity ratio. In discordant subgroups of severe AS, the CF reclassified patients to moderate AS in 40% in the low flow (LF), low gradient (LG), and low ejection fraction (EF) group; 53% in the LF, LG, and normal EF group; and 68% in the LF, high gradient, and normal EF group. Conclusions: CF of 1.13 derived from MDCTA improved the accuracy of TTE‐derived LVOT area and AVA and improved correlation with hemodynamic variables in AS patients. Reclassification of AS patients using CF may have clinical applicability for patient selection for early intervention. … (more)
- Is Part Of:
- Echocardiography. Volume 37:Issue 2(2020)
- Journal:
- Echocardiography
- Issue:
- Volume 37:Issue 2(2020)
- Issue Display:
- Volume 37, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2020-0037-0002-0000
- Page Start:
- 196
- Page End:
- 206
- Publication Date:
- 2020-01-31
- Subjects:
- aortic valve area -- continuity equation -- correction factor -- echocardiography -- LVOT area -- multidetector computed tomography
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.14601 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12996.xml