Validation of an analytical method using HPLC–MS/MS to quantify osimertinib in human plasma and supplementary stability results. (3rd February 2020)
- Record Type:
- Journal Article
- Title:
- Validation of an analytical method using HPLC–MS/MS to quantify osimertinib in human plasma and supplementary stability results. (3rd February 2020)
- Main Title:
- Validation of an analytical method using HPLC–MS/MS to quantify osimertinib in human plasma and supplementary stability results
- Authors:
- van Veelen, Ard
van Geel, Robin
de Beer, Yvo
Dingemans, Anne‐Marie
Stolk, Leo
ter Heine, Rob
de Vries, Frank
Croes, Sander - Abstract:
- Abstract: A new method for quantification of osimertinib (OSIM) in human plasma using a high‐performance liquid chromatography–tandem mass spectrometry method was developed and validated. Methanol was used for protein precipitation and pazopanib as internal standard. Separation was performed on a HyPURITY®C18 analytical column (50 × 2.1 mm; 3 μm) using a gradient elution of ammonium acetate in water and ammonium acetate in methanol, both acidified with formic acid 0.1%. Detection and quantification of OSIM and pazopanib was performed using a triple quadruple mass spectrometer after electrospray ionization. This method led to robust results, as the selectivity, carryover, precision and accuracy all met pre‐specified requirements. OSIM was stable in human serum when stored at −80°C. Reduced stability was found when stored at 2–4°C or room temperature. Degradation of OSIM slowed down in EDTA–plasma and acidified human serum. The limited stability of OSIM at room temperature should be considered for transport and sample preparation. Plasma samples should be frozen as soon as possible and sample preparation should be performed on dry‐ice. In the future, EDTA–plasma and sample acidification may be used to improve OSIM stability at room temperature. However, more research and validation of such an approach are required.
- Is Part Of:
- Biomedical chromatography. Volume 34:Number 4(2020)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 34:Number 4(2020)
- Issue Display:
- Volume 34, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2020-0034-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-02-03
- Subjects:
- analysis -- osimertinib -- room temperature -- stability -- validation
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.4771 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12988.xml