Dosing Errors Made by Paramedics During Pediatric Patient Simulations After Implementation of a State-Wide Pediatric Drug Dosing Reference. (3rd March 2020)
- Record Type:
- Journal Article
- Title:
- Dosing Errors Made by Paramedics During Pediatric Patient Simulations After Implementation of a State-Wide Pediatric Drug Dosing Reference. (3rd March 2020)
- Main Title:
- Dosing Errors Made by Paramedics During Pediatric Patient Simulations After Implementation of a State-Wide Pediatric Drug Dosing Reference
- Authors:
- Hoyle, John D.
Ekblad, Glenn
Hover, Tracy
Woodwyk, Alyssa
Brandt, Richard
Fales, Bill
Lammers, Richard L. - Abstract:
- Abstract: Background: Drug dosing errors occur at a high rate for prehospital pediatric patients. To reduce errors, Michigan implemented a state-wide pediatric dosing reference (PDR), with doses listed in milliliters, the requirement that doses be drawn into a smaller syringe from a pre-loaded syringe using a stopcock, and dilution of certain drugs to different concentrations. Purpose: To evaluate the rate of medication errors, including errors of omission and commission, after implementation of a state-wide PDR. Methods: EMS crews from 15 agencies completed 4 validated, simulation scenarios: an infant seizing, an infant cardiac arrest, an 18-month-old with a burn, and 5-year-old with anaphylactic shock. Agencies were private, public, not-for-profit, for-profit, urban, rural, fire-based, and third service. EMS crews used their regular equipment and were required to carry out all the steps to administer a drug dose. Two evaluators scored crew performance via direct observation and video review. An error was defined as ≥ 20% difference compared to the weight-appropriate dose. Descriptive statistics were utilized. Results: A total of 142 simulations were completed. The majority of crews were (58.3%) Emergency Medical Technician-Paramedic (EMTP)/EMTP. For the cardiac arrest scenario, 51/70 (72.9%; 95% CI: 60.9%, 82.8%) epinephrine doses were correct. There were 6 (8.6%, 95% CI: 2.0%, 15.1%) 10-fold overdoses and one (1.4%; 95% CI: –1.4%, 4.2%), 10-fold under dose. In the seizureAbstract: Background: Drug dosing errors occur at a high rate for prehospital pediatric patients. To reduce errors, Michigan implemented a state-wide pediatric dosing reference (PDR), with doses listed in milliliters, the requirement that doses be drawn into a smaller syringe from a pre-loaded syringe using a stopcock, and dilution of certain drugs to different concentrations. Purpose: To evaluate the rate of medication errors, including errors of omission and commission, after implementation of a state-wide PDR. Methods: EMS crews from 15 agencies completed 4 validated, simulation scenarios: an infant seizing, an infant cardiac arrest, an 18-month-old with a burn, and 5-year-old with anaphylactic shock. Agencies were private, public, not-for-profit, for-profit, urban, rural, fire-based, and third service. EMS crews used their regular equipment and were required to carry out all the steps to administer a drug dose. Two evaluators scored crew performance via direct observation and video review. An error was defined as ≥ 20% difference compared to the weight-appropriate dose. Descriptive statistics were utilized. Results: A total of 142 simulations were completed. The majority of crews were (58.3%) Emergency Medical Technician-Paramedic (EMTP)/EMTP. For the cardiac arrest scenario, 51/70 (72.9%; 95% CI: 60.9%, 82.8%) epinephrine doses were correct. There were 6 (8.6%, 95% CI: 2.0%, 15.1%) 10-fold overdoses and one (1.4%; 95% CI: –1.4%, 4.2%), 10-fold under dose. In the seizure scenario, 28/50 (56.0%; 95% CI: 42.2%, 69.8%) benzodiazepine doses were correct; 6/18 (33.3%; 95% CI: 11.5%, 55.1%) drug dilutions were incorrect resulting in dosing errors. Unrecognized air was frequently entrained into the administration syringe resulting in under doses. Overall, 31.2% (95% CI: 25.5%, 36.6%) of drug doses were incorrect. Obtaining an incorrect weight led to a drug dosing error in 18/142 (12.7%, 95% CI: 7.2%, 18.2%) cases. Errors of omission included failure to check blood sugar in the seizure scenario and failure to administer epinephrine and a fluid bolus in anaphylactic shock. Conclusion: Despite implementation of a PDR, dosing errors, including 10-fold errors, still occur at a high rate. Errors occur with dilution and length-based tape use. Further error reduction strategies, beyond a PDR and that target errors of omission, are needed for pediatric prehospital drug administration. … (more)
- Is Part Of:
- Prehospital emergency care. Volume 24:Number 2(2020)
- Journal:
- Prehospital emergency care
- Issue:
- Volume 24:Number 2(2020)
- Issue Display:
- Volume 24, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 24
- Issue:
- 2
- Issue Sort Value:
- 2020-0024-0002-0000
- Page Start:
- 204
- Page End:
- 213
- Publication Date:
- 2020-03-03
- Subjects:
- pediatric -- drug dosing -- patient safety -- medication errors -- adverse drug events
362.18 - Journal URLs:
- http://informahealthcare.com/loi/pec ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/10903127.2019.1619002 ↗
- Languages:
- English
- ISSNs:
- 1090-3127
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6605.917000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12983.xml