Influence of Thoracic Endovascular Repair on Aortic Morphology in Patients Treated for Blunt Traumatic Aortic Injuries: Long Term Outcomes in a Multicentre Study. (March 2020)
- Record Type:
- Journal Article
- Title:
- Influence of Thoracic Endovascular Repair on Aortic Morphology in Patients Treated for Blunt Traumatic Aortic Injuries: Long Term Outcomes in a Multicentre Study. (March 2020)
- Main Title:
- Influence of Thoracic Endovascular Repair on Aortic Morphology in Patients Treated for Blunt Traumatic Aortic Injuries: Long Term Outcomes in a Multicentre Study
- Authors:
- Gennai, Stefano
Leone, Nicola
Andreoli, Francesco
Munari, Elisa
Berchiolli, Raffaella
Arcuri, Luciana
Tusini, Nicola
Marcheselli, Luigi
Silingardi, Roberto - Abstract:
- Abstract : Objective: The aim of this study was to evaluate aortic remodelling and associated complications in patients treated by thoracic endovascular aneurysm repair (TEVAR) for blunt traumatic aortic injuries (BTAI). Methods: This was a retrospective, observational, multicentre study. Remodelling was considered as aortic diameter variations of >2 mm and distal graft and aortic axis angle modification measured by computed tomography angiography (CTA). The predefined levels of measurement were the proximal end of the graft (D1: landing in zone [LZ] 2; D2: LZ 3); distal end (D3); and control measurement (D4) 15 mm beyond D3. Survival, procedure, graft, and/or radiation exposure related complications were registered. CTA was required within three months and at one, six, and 10 years post-operatively. Results: Between 2004 and 2017 52 patients were treated; 47 were included for remodelling analysis (five immediate deaths were excluded); median age was 47 years (range 20–80 years). Mean TEVAR oversizing was 19.6% ± 9.7% (range 5%–35%). Following a median follow up of 67.4 ± 56.1 months (range 14–153 months) survival at one, three, six, and 10 years was 90.4% (standard error [SE] 4.1%), 88.3% (SE 4.5%) 84.8% (SE 5.5%), and 84.8% (SE 5.5%), respectively. There were no procedure/graft related complications except for one late intramural haematoma that required re-intervention. Freedom from aortic remodelling at one, six, and 10 years was 85.1% (SE 5.2%), 30.9% (SE 8.6%), andAbstract : Objective: The aim of this study was to evaluate aortic remodelling and associated complications in patients treated by thoracic endovascular aneurysm repair (TEVAR) for blunt traumatic aortic injuries (BTAI). Methods: This was a retrospective, observational, multicentre study. Remodelling was considered as aortic diameter variations of >2 mm and distal graft and aortic axis angle modification measured by computed tomography angiography (CTA). The predefined levels of measurement were the proximal end of the graft (D1: landing in zone [LZ] 2; D2: LZ 3); distal end (D3); and control measurement (D4) 15 mm beyond D3. Survival, procedure, graft, and/or radiation exposure related complications were registered. CTA was required within three months and at one, six, and 10 years post-operatively. Results: Between 2004 and 2017 52 patients were treated; 47 were included for remodelling analysis (five immediate deaths were excluded); median age was 47 years (range 20–80 years). Mean TEVAR oversizing was 19.6% ± 9.7% (range 5%–35%). Following a median follow up of 67.4 ± 56.1 months (range 14–153 months) survival at one, three, six, and 10 years was 90.4% (standard error [SE] 4.1%), 88.3% (SE 4.5%) 84.8% (SE 5.5%), and 84.8% (SE 5.5%), respectively. There were no procedure/graft related complications except for one late intramural haematoma that required re-intervention. Freedom from aortic remodelling at one, six, and 10 years was 85.1% (SE 5.2%), 30.9% (SE 8.6%), and 24.7% (SE 8.8%), respectively. The increase in D1/D2 and D3 diameters were influenced by time from intervention (both p < .001), age ( p < .001 and p = .002, respectively) and sealing in zone 2 ( p = .027 and p = .042, respectively). For every 10% increase in oversizing, proximal neck diameter remodelling was 3.4% ( p = .05). The distal axis decreased over time ( p < .001; significant between three and six years). Conclusion: TEVAR is safe for BTAI in the mid to long term. This study reports a correlation between time, oversizing, and remodelling, but the level of adverse events was low. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 59:Number 3(2020)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 59:Number 3(2020)
- Issue Display:
- Volume 59, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 59
- Issue:
- 3
- Issue Sort Value:
- 2020-0059-0003-0000
- Page Start:
- 428
- Page End:
- 436
- Publication Date:
- 2020-03
- Subjects:
- Blunt injury -- Endovascular technique -- Thoracic aorta
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2019.05.008 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12941.xml