The efficacy of metal artifact reduction (MAR) algorithm in cone‐beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants. Issue 2 (28th August 2019)
- Record Type:
- Journal Article
- Title:
- The efficacy of metal artifact reduction (MAR) algorithm in cone‐beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants. Issue 2 (28th August 2019)
- Main Title:
- The efficacy of metal artifact reduction (MAR) algorithm in cone‐beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants
- Authors:
- Sheikhi, Mahnaz
Behfarnia, Parichehr
Mostajabi, Mahdis
Nasri, Naeimeh - Abstract:
- Abstract: Background: The aim of the present study was to investigate the impact of metal artifact reduction (MAR) algorithm of cone‐beam computed tomography (CBCT) on the diagnostic accuracy of fenestration and dehiscence around dental implants. Methods: Twenty‐three dental implants were placed adjacent to the dehiscence and 23 adjacent to the fenestration defects on bovine bone blocks. The blocks were scanned with CBCT unit in two modes, with and without MAR algorithm. The area under the receiver operator characteristic (ROC) curves (Az value), specificity, sensitivity, positive predictive value, negative predictive value, and accuracy were determined for all modes. Results: For both defects, the Az values were higher in off MAR condition. The values of sensitivity, positive predictive value, negative predictive value, and accuracy, were higher in off MAR condition for both defects. However, the specificity in both defects in the two modes was equal. Conclusion: The MAR algorithm in CBCT unit may not be helpful in increasing the diagnostic accuracy of fenestration and dehiscence around dental implants.
- Is Part Of:
- Journal of periodontology. Volume 91:Issue 2(2020)
- Journal:
- Journal of periodontology
- Issue:
- Volume 91:Issue 2(2020)
- Issue Display:
- Volume 91, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 91
- Issue:
- 2
- Issue Sort Value:
- 2020-0091-0002-0000
- Page Start:
- 209
- Page End:
- 214
- Publication Date:
- 2019-08-28
- Subjects:
- artifacts -- cone‐beam computed tomography -- dental implants -- periodontal diseases
Periodontics -- Periodicals
617.632 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1902/(ISSN)1943-3670 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/JPER.18-0433 ↗
- Languages:
- English
- ISSNs:
- 0022-3492
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12925.xml