Biomechanical analysis of sagittal correction parameters for surgical instrumentation with pedicle subtraction osteotomy in adult spinal deformity. (January 2020)
- Record Type:
- Journal Article
- Title:
- Biomechanical analysis of sagittal correction parameters for surgical instrumentation with pedicle subtraction osteotomy in adult spinal deformity. (January 2020)
- Main Title:
- Biomechanical analysis of sagittal correction parameters for surgical instrumentation with pedicle subtraction osteotomy in adult spinal deformity
- Authors:
- Benoit, David
Wang, Xiaoyu
Crandall, Dennis G.
Aubin, Carl-Éric - Abstract:
- Abstract: Background: High complication rate has been documented in spinal instrumentation with pedicle subtraction osteotomy. The objective was to analyze the biomechanics of spinal instrumentation with pedicle subtraction osteotomy as functions of three instrumentation parameters. Methods: Patient-specific biomechanical computer models of 3 adult patients who were instrumented with pedicle subtraction osteotomy were used to simulate the actual instrumentations and alternative instrumentations derived by varying instrumentation parameters: pedicle subtraction osteotomy wedge angle and rod contouring angle, location of the osteotomy, and number of rods (2 vs. 4). Findings: A change of the sagittal correction by +7.5° (−7.5°) resulted in a change in the screw axial forces and rods bending loads around the osteotomy by +38% (−19%) and +28% (−11%), respectively. The bending moments in the rods were 31% lower at the osteotomy site when it was located at one level above, and 20% higher when it was located at a level below. Additional rods allowed the rod bending and screw axial loads to be reduced by 24% and 22%, respectively. Interpretation: The amount of sagittal correction was positively correlated with loads sustained by the screws and rods. Rods were subjected to higher bending loads at the pedicle subtraction osteotomy site when it was done at a lower level. A 4-rod construct is an effective way to reduce the risk of rod breakage by reducing the loads sustained by the rods.Abstract: Background: High complication rate has been documented in spinal instrumentation with pedicle subtraction osteotomy. The objective was to analyze the biomechanics of spinal instrumentation with pedicle subtraction osteotomy as functions of three instrumentation parameters. Methods: Patient-specific biomechanical computer models of 3 adult patients who were instrumented with pedicle subtraction osteotomy were used to simulate the actual instrumentations and alternative instrumentations derived by varying instrumentation parameters: pedicle subtraction osteotomy wedge angle and rod contouring angle, location of the osteotomy, and number of rods (2 vs. 4). Findings: A change of the sagittal correction by +7.5° (−7.5°) resulted in a change in the screw axial forces and rods bending loads around the osteotomy by +38% (−19%) and +28% (−11%), respectively. The bending moments in the rods were 31% lower at the osteotomy site when it was located at one level above, and 20% higher when it was located at a level below. Additional rods allowed the rod bending and screw axial loads to be reduced by 24% and 22%, respectively. Interpretation: The amount of sagittal correction was positively correlated with loads sustained by the screws and rods. Rods were subjected to higher bending loads at the pedicle subtraction osteotomy site when it was done at a lower level. A 4-rod construct is an effective way to reduce the risk of rod breakage by reducing the loads sustained by the rods. Highlights: Pedicle subtraction wedge angle was positively correlated with construct loads. More caudally located pedicle subtraction had higher construct loads. 4-rod constructs (vs. 2 rods) reduced the construct loads. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 71(2020)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 71(2020)
- Issue Display:
- Volume 71, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 71
- Issue:
- 2020
- Issue Sort Value:
- 2020-0071-2020-0000
- Page Start:
- 45
- Page End:
- 52
- Publication Date:
- 2020-01
- Subjects:
- Biomechanical modeling -- Pedicle subtraction osteotomy -- Spinal instrumentation -- Adult spinal deformity -- Sagittal balance
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.10.014 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12919.xml