Reliability comparison of natural convection and forced circulation configurations of a FBR thermo-siphon decay heat removal system. (March 2020)
- Record Type:
- Journal Article
- Title:
- Reliability comparison of natural convection and forced circulation configurations of a FBR thermo-siphon decay heat removal system. (March 2020)
- Main Title:
- Reliability comparison of natural convection and forced circulation configurations of a FBR thermo-siphon decay heat removal system
- Authors:
- Ramakrishnan, M.
John Arul, A.
Parthasarathy, U.
Bhuvana, V.
Magesh Mari Raj, V.
Chithira, P. - Abstract:
- Abstract: Natural convection based passive decay heat removal systems are increasingly being deployed in the newer designs of nuclear reactors with the expectation that they enhance reliability and robustness owing to the elimination of reliance on human operators and external electrical power supply. In the absence of demonstrated experience with passive systems, difficulty in testing them on the field and possible range of phenomena which can degrade their performance, in some designs part of the redundant passive circuits are fitted with pumps to alleviate concerns regarding passive system performance. In this study the two types of designs, one with a set of 4 passive thermo-siphon loops and another with electro-magnetic pumps in part or all of the thermo-siphon loops are studied to bring out the reliability aspects. The decay heat removal function failure frequency is analyzed considering, electromagnetic pump integrity, changes in human interaction aspects for the two different configurations. It is observed that the introduction of electromagnetic pumps in two out of four loops increases the decay heat removal function failure frequency by approximately 64%. If electromagnetic pumps are introduced in all the four loops, the decay heat removal function failure frequency increases by an order. The results are highly sensitive to electromagnetic pump reliability. This study indicates that, there is no change in the uncertainty propagated from input parameters to responseAbstract: Natural convection based passive decay heat removal systems are increasingly being deployed in the newer designs of nuclear reactors with the expectation that they enhance reliability and robustness owing to the elimination of reliance on human operators and external electrical power supply. In the absence of demonstrated experience with passive systems, difficulty in testing them on the field and possible range of phenomena which can degrade their performance, in some designs part of the redundant passive circuits are fitted with pumps to alleviate concerns regarding passive system performance. In this study the two types of designs, one with a set of 4 passive thermo-siphon loops and another with electro-magnetic pumps in part or all of the thermo-siphon loops are studied to bring out the reliability aspects. The decay heat removal function failure frequency is analyzed considering, electromagnetic pump integrity, changes in human interaction aspects for the two different configurations. It is observed that the introduction of electromagnetic pumps in two out of four loops increases the decay heat removal function failure frequency by approximately 64%. If electromagnetic pumps are introduced in all the four loops, the decay heat removal function failure frequency increases by an order. The results are highly sensitive to electromagnetic pump reliability. This study indicates that, there is no change in the uncertainty propagated from input parameters to response parameters, there is no significant advantage in terms of flexibility gained for certain operator actions and higher levels of reliability need to be achieved for the electromagnetic pump if it is to be introduced in all the four loops as compared to introduction in only two loops. Highlights: Reliability comparison of a thermo-siphon DHRS of a FBR under natural convection and forced circulation configurations. Impact of design and critical parametric uncertainty owing to the introduction of EM pumps in the thermo-siphon loops. Observation of possibility of decrease in reliability due to the introduction of electromagnetic pumps. Estimation of reliability targets for electromagnetic pumps to maintain passive system reliability level. Combined treatment of hardware, functional failures and human reliability aspects. … (more)
- Is Part Of:
- Progress in nuclear energy. Volume 121(2020)
- Journal:
- Progress in nuclear energy
- Issue:
- Volume 121(2020)
- Issue Display:
- Volume 121, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 121
- Issue:
- 2020
- Issue Sort Value:
- 2020-0121-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Passive system reliability -- Decay heat -- Electromagnetic pump -- Sensitivity -- Fault tree
Nuclear energy -- Periodicals
Nuclear engineering -- Periodicals
333.7924 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01491970 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.pnucene.2020.103242 ↗
- Languages:
- English
- ISSNs:
- 0149-1970
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6870.542000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12898.xml