Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach. (February 2020)
- Record Type:
- Journal Article
- Title:
- Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach. (February 2020)
- Main Title:
- Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach
- Authors:
- Cho, Sanghoon
Lim, Sunho
Kim, Changhwan
Wi, Sunhee
Kwon, Taejin
Youn, Won Sik
Lee, Sang Hyun
Kang, Bo Sun
Cho, Seungryong - Abstract:
- Highlights: Use of anti-scatter grids with high grid-ratio in CBCT is justified. Sparse-view CBCT scanning is desirable when using such grids. Exposure per view needs to be increased to balance the noise. The proposed method increases low-contrast visibility in CBCT. Abstract: Purpose: Anti-scatter grids suppress the scatter substantially thus improving image contrast in radiography. However, its active use in cone-beam CT for the purpose of improving contrast-to-noise ratio (CNR) has not been successful mainly due to the increased noise related to Poisson statistics of photons. This paper proposes a sparse-view scanning approach to address the above issue. Method: Compared to the conventional cone-beam CT imaging framework, the proposed method reduces the number of projections and increases exposure in each projection to enhance image quality without an additional cost of radiation dose to patients. For image reconstruction from sparse-view data, an adaptive-steepest-descent projection-onto-convex-sets (ASD POCS) algorithm regularized by total-variation (TV) minimization was adopted. Contrast and CNR with various scattering conditions were evaluated in projection domain by a simulation study using GATE. Then we evaluated contrast, resolution, and image uniformity in CT image domain with Catphan phantom. A head phantom with soft-tissue structures was also employed for demonstrating a realistic application. A virtual grid-based estimation and reduction of scatter has alsoHighlights: Use of anti-scatter grids with high grid-ratio in CBCT is justified. Sparse-view CBCT scanning is desirable when using such grids. Exposure per view needs to be increased to balance the noise. The proposed method increases low-contrast visibility in CBCT. Abstract: Purpose: Anti-scatter grids suppress the scatter substantially thus improving image contrast in radiography. However, its active use in cone-beam CT for the purpose of improving contrast-to-noise ratio (CNR) has not been successful mainly due to the increased noise related to Poisson statistics of photons. This paper proposes a sparse-view scanning approach to address the above issue. Method: Compared to the conventional cone-beam CT imaging framework, the proposed method reduces the number of projections and increases exposure in each projection to enhance image quality without an additional cost of radiation dose to patients. For image reconstruction from sparse-view data, an adaptive-steepest-descent projection-onto-convex-sets (ASD POCS) algorithm regularized by total-variation (TV) minimization was adopted. Contrast and CNR with various scattering conditions were evaluated in projection domain by a simulation study using GATE. Then we evaluated contrast, resolution, and image uniformity in CT image domain with Catphan phantom. A head phantom with soft-tissue structures was also employed for demonstrating a realistic application. A virtual grid-based estimation and reduction of scatter has also been implemented for comparison with the real anti-scatter grid. Results: In the projection domain evaluation, contrast and CNR enhancement was observed when using an anti-scatter grid compared to the virtual grid. In the CT image domain, the proposed method produced substantially higher contrast and CNR of the low-contrast structures with much improved image uniformity. Conclusion: We have shown that the proposed method can provide high-quality CBCT images particularly with an increased contrast of soft-tissue at a neutral dose for image-guidance. … (more)
- Is Part Of:
- Physica medica. Volume 70(2020)
- Journal:
- Physica medica
- Issue:
- Volume 70(2020)
- Issue Display:
- Volume 70, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 70
- Issue:
- 2020
- Issue Sort Value:
- 2020-0070-2020-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2020-02
- Subjects:
- Cone-beam CT (CBCT) -- Anti-scatter grid -- Scatter correction
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.01.004 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12889.xml