Farace, Paolo - Abstract:
- Highlights: A comprehensive methodology for proton pencil-beam crossing titanium implants. Implementing a proper CT calibration. Effects of artefacts on CT images and their reduction by a dedicated algorithm. Evaluation of the computation dose engine, comparing pencil-beam vs Monte-Carlo algorithms. Abstract: Purpose: To present a planning strategy for proton pencil-beam scanning when titanium implants need to be crossed by the beam. Methods: We addressed three issues: the implementation of a CT calibration curve to assign to titanium the correct stopping power; the effect of artefacts on CT images and their reduction by a dedicated algorithm; the differences in dose computation depending on the dose engine, pencil-beam vs Monte-Carlo algorithms. We performed measurement tests on a simple cylinder phantom and on a real implant. These phantoms were irradiated with three geometries (single spots, uniform mono-energetic layer and uniform box), measuring the exit dose either by radio-chromic film or multi-layer ionization chamber. The procedure was then applied on two patients treated for chordoma. Results: We had to set in the calibration curve a mass density equal to 4.37 g/cm 3 to saturated Hounsfield Units, in order to have the correct stopping power assigned to titanium in TPS. CT artefact reduction algorithm allowed a better reconstruction of the shape and size of the implant. Monte-Carlo resulted accurate in computing the dose distribution whereas the pencil-beamHighlights: A comprehensive methodology for proton pencil-beam crossing titanium implants. Implementing a proper CT calibration. Effects of artefacts on CT images and their reduction by a dedicated algorithm. Evaluation of the computation dose engine, comparing pencil-beam vs Monte-Carlo algorithms. Abstract: Purpose: To present a planning strategy for proton pencil-beam scanning when titanium implants need to be crossed by the beam. Methods: We addressed three issues: the implementation of a CT calibration curve to assign to titanium the correct stopping power; the effect of artefacts on CT images and their reduction by a dedicated algorithm; the differences in dose computation depending on the dose engine, pencil-beam vs Monte-Carlo algorithms. We performed measurement tests on a simple cylinder phantom and on a real implant. These phantoms were irradiated with three geometries (single spots, uniform mono-energetic layer and uniform box), measuring the exit dose either by radio-chromic film or multi-layer ionization chamber. The procedure was then applied on two patients treated for chordoma. Results: We had to set in the calibration curve a mass density equal to 4.37 g/cm 3 to saturated Hounsfield Units, in order to have the correct stopping power assigned to titanium in TPS. CT artefact reduction algorithm allowed a better reconstruction of the shape and size of the implant. Monte-Carlo resulted accurate in computing the dose distribution whereas the pencil-beam algorithm failed due to sharp density interfaces between titanium and the surrounding material. Finally, the treatment plans obtained on two patients showed the impact of the dose engine algorithm, with 10–20% differences between pencil-beam and Monte-Carlo in small regions distally to the titanium screws. Conclusion: The described combination of CT calibration, artefacts reduction and Monte-Carlo computation provides a reliable methodology to compute dose in patients with titanium implants. … (more)
- Is Part Of:
- Physica medica. Volume 70(2020)
- Journal:
- Physica medica
- Issue:
- Volume 70(2020)
- Issue Display:
- Volume 70, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 70
- Issue:
- 2020
- Issue Sort Value:
- 2020-0070-2020-0000
- Page Start:
- 28
- Page End:
- 38
- Publication Date:
- 2020-02
- Subjects:
- Proton therapy -- Pencil beam scanning -- Titanium implants -- Metal artifacts -- Monte Carlo
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.01.003 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12889.xml